10.31
The Sample Data and Inventory Tables
System Reporter 2.8 3PAR System Reporter User’s Guide
d_qlen DOUBLE PRECISION NOT
NULL
Difference between qlen value from last
sample for the same object.
busy DOUBLE PRECISION NOT
NULL
Time in microsecs that the device has been
busy.
d_busy DOUBLE PRECISION NOT
NULL
Difference between busy value from last
sample for the same object.
rcount DOUBLE PRECISION NOT
NULL
Total number of reads since the object was
first created or restarted.
d_rcount DOUBLE PRECISION NOT
NULL
Difference between rcount value from last
sample for the same object.
rbytes DOUBLE PRECISION NOT
NULL
Total number of bytes read since the object
was first created or restarted
d_rbytes DOUBLE PRECISION NOT
NULL
Difference between rbytes value from last
sample for the same object.
rerror DOUBLE PRECISION NOT
NULL
Total number of read errors since the object
was first created or restarted
d_rerror DOUBLE PRECISION NOT
NULL
Difference between error value from last
sample for the same object.
rdrops DOUBLE PRECISION NOT
NULL
Total number of dropped reads since the
object was first created or restarted.
d_rdrops DOUBLE PRECISION NOT
NULL
Difference between rdrops value from last
sample for the same object.
rticks DOUBLE PRECISION NOT
NULL
Total number of ticks (microsecs) taken by
read operations since the object was first
created or restarted.
Table 10-19. Common Performance Columns