Table 57 Metric (continued)
Data TablesDescriptionMetrics
statcpuPercentage idle time for the nodeidle_perc
statport, statpd,
nl
Total utilization per second. For instance,
when the PD utilization exceeds a given
total_utilperc
statpd_nl7,statpd_fc10,
nl
high (say 90%) utilization meaning that
statpd_fc15, statpd_ssd150, statld,
nl
90% of the time there is some IO
operation outstanding at the PD.
statvlun
Direction
Specifies whether the Metric should be less than (<) or greater than (>) the Limit Value for the alert
to be generated.
Limit Value
Specifies the value that the Metric is compared to. This should be a number.
Limit Count
The alert will only be generated if the number of objects for which the Metric exceeds the Limit
Value (in the direction specified by Direction) is greater than Limit Count in any given sample. This
should be an integer.
Condition
Specifies the condition (min_read_iops, min_write_iops, min_total_iops) that should be monitored.
Condition Value
Specifies the condition value.
Recipient
Email address to which the alert email should be sent.
Example of an Alert Rule
Figure 47 (page 121) shows an example of a configured alert. In this example, System Reporter
will send an email alert to email@address each time it inserts a high-resolution sample in which
more than 0 (Limit Count) VLUNs (including VLUNs in all systems) has a total (reads and writes
included) average service time in millisecs of greater than (>) 1000 (Limit Value).
Figure 47 Example of an alert rule
An example of the email alert is shown Figure 48 (page 122):
Configuring Rules for Email Alerts 121