Hp StorageWorks 1510i Modular Smart Array Manual do Utilizador Página 1

Consulte online ou descarregue Manual do Utilizador para Armazenamento Hp StorageWorks 1510i Modular Smart Array. HP StorageWorks 1510i Modular Smart Array User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 154
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes

Resumo do Conteúdo

Página 1 - Interface user guide

HP StorageWorks1510i Modular Smart Array Command LineInterface user guideactive/active firmware 2.xPart number: 383074–002Second edition: May 2008

Página 2

Document conventions and symbolsTable 1 Document conventionsConventionElementBlue text: Table 1 Cross-reference links and e-mail addressesBlue, underl

Página 3 - Contents

set unit_idDescription Assigns a unique user-friendly name (alias) to a LUN. A user-defined namemakes it easier to identify specific LUNs in other config

Página 4

show acl_entryDescription Shows the access control lists for all initiators on a specified iSCSI target,or on all targets.NOTE:If access controls are d

Página 5

show adu_pageDescription Shows the specified ADU (Array Diagnostic Utility) XML report. You mustcapture the output in a capture file using the procedure

Página 6

show arpDescription Shows the ARP table of the storage ports.Syntaxshow arpOperands NoneExampleCLI> show arpIP Address MAC Address--------------- -

Página 7

show auto_path_changeDescription Shows whether implicit (automatic) path changing enabled and lists thecriteria that must be met for an automatic LUN

Página 8

show boxDescription Displays information about the specified hard drive storage enclosure. If abox number is not entered, information on all attached s

Página 9

show cacheinfoDescription Displays controller cache status.Syntaxshow cacheinfoOperands NoneExampleCLI> show cacheinfo00000001 LINES: UNASSIGNED NO

Página 10 - HP technical support

show certificateDescription Displays the SSL certificate being used by the management interface.Syntaxshow certificate [data]Operandsdata[Optional] When

Página 11 - Documentation feedback

show discoveryDescription Shows the status of SLP/iSNS discovery on the iSCSI targets.Syntax show discovery [alias=<target_alias_name>]Operands

Página 12 - About this guide

show disksDescription Lists the disks and information pertaining to them. The following informationis displayed:•Disknumber• Enclosure box and bay num

Página 13 - 1CLIsetupandoverview

• Error messages• Operating system type and revision level• Detailed questionsHP installation and configuration assistanceStorage management and networ

Página 14 - Management Utility user guide

show drive_reportDescription Displays a list of system smart components that require an update. Anexample smartcomponent is a hard drive.NOTE:To use t

Página 15

show eventlogDescription Shows a list ofevents logged by the controller.Syntaxshow eventlogOperands NoneExampleCLI> show eventlogTIME CLASS SUB DET

Página 16 - CLI Overview

show globalsDescription Displays the following global settings:•Systemname• Rebuild and expand priority settings•Readandwritecache settings• EMU and p

Página 17 - CLI help

show initiatorDescription Displays all configured iSCSI initiators.Syntax show initiator [alias=<initiator_alias_name>]Operands alias=<initiat

Página 18 - CLI setup and overview

show ipDescription Shows the IP addresses configured for iSCSI ports.Syntax show ip [port=<port_name>]Operands port=<port_name>[Optional] L

Página 19 - Configure logical drives

show iscsi_keysDescription Shows the iSCSI login parameter keys for the iSCSI targets.Syntax show iscsi_keys [alias=<target_alias_name>]Operands

Página 20 - Initial configuration sequence

show isnsDescription Shows the iSNS parameters.Syntaxshow isnsOperands NoneExampleCLI>show isnsiSNS Service is enablediSNS Server Discovery Mode is

Página 21

show isns_serverDescription Shows a list of configured iSNS servers.Syntaxshow isns_serverOperands NoneExampleCLI> show isns_serverAlias Name IP Add

Página 22 - Enabling iSNS

show managementDescription Displays current management settings for the controller management ports.Syntaxshow managementOperands NoneExampleCLI> s

Página 23 - Enable SLP disc

show mib2Description Shows SNMP MIB-II data for the storage ports. If one of the optionalparameters is supplied, output is limited to only show the sp

Página 24

12About this guide

Página 25 - 3 Command reference

show perfDescription Displays controller performance information that was previously gatheredby initiatingthe start perf command.Syntaxshow perf [logi

Página 26 - Alphabetical l

show portDescription Shows status information for the storage ports.Syntax show port [<port>]Operands <port>[Optional] The name of the phy

Página 27

show portalDescription Displays all configured iSCSI portals, including the alias name, IP address,port, and portal group binding.Syntax show portal [a

Página 28

show portal_groupDescription Shows all configured iSCSI portal groups.Syntax show portal_group [alias=<pg_alias_name>]Operands alias=<pg_alias

Página 29

show profileDescription Displays detailed attribute information about supported host modes(operating systems).Syntax show profile [ProfileName]Operands

Página 30

show preferred_pathDescription Displays the current path (controller owner) for each LUN.Syntaxshow preferred_pathOperands NoneExampleCLI> show pre

Página 31

show proxystatsDescription For dual-controller configurations only, displays information aboutcommands that have been passed from one controller to the

Página 32 - Alias: server1.test

show routeDescription Shows the routing table for the storage ports.Syntaxshow routeOperands NoneExampleCLI> show routeDestination Gateway Netmask

Página 33 - Alias: portal1.test

show serviceDescription Displays the current management interface network services configuration.Syntaxshow serviceOperands NoneExampleCLI> show ser

Página 34

show snmpDescription Displays the current settings for the embedded SNMP agent.Syntaxshow snmpOperands NoneExampleCLI> show snmpCommunity String: p

Página 35

1CLIsetupandoverviewThe Command Line Interface (CLI) is used to configure and manage the array controller and its storage.Tasks include configuring logi

Página 36

show targetDescription Displays all configured iSCSI targets.Syntax show target [alias=<target_alias_name<]Operands alias=<target_alias_name&g

Página 37

show taskstatsDescription Displays controller task statistics.Syntaxshow taskstatsOperands NoneExampleCLI> show taskstatsCurrent task stats for Ini

Página 38

show tech_supportDescription Executes a macro command that runs all of the CLI show commands. Youshould redirect the screen output to a file before exe

Página 39

show tgt_statsDescription Shows iSCSI login, session, and connection statistics for an iSCSI target.Syntax show tgt_stats [target=<target_alias_nam

Página 40

show this_controller|other_controllerDescription Displays configuration information for the specified controller, such as:•Serialnumber• Hardware/softwa

Página 41

show unitDescription Displays information about the specified LUN, or all defined LUNs. Theshow unit and show units commands are identical in functional

Página 42

See also • add unit• bind unit• delete unit• set unit• accept unit• expand unit• extend unit• migrate unit• set unit_id• show unit_id• unbind unitnewp

Página 43

show unit_idDescription Displays the user-defined name (alias) assigned to a LUN.Syntax show unit_id <unit>Operands <unit>The LUN number(0-

Página 44

show versionDescription Displays firmware version and hardware revision information for the MSAchassis, system modules, and attached hard drive storage

Página 45

start perfDescription Starts the collection of controller performance analysis data.Syntaxstart perfOperands NoneExampleCLI> start perfPerformance

Página 46

2. Launch PuTTY on a PC that is connected to the same LAN as the MSA1510i.3. Enter the IP address of the MSA1510i management port in the Host Name (or

Página 47

stop perfDescription Stops the collection of controller performance analysis data.Syntaxstop perfOperands NoneExampleCLI> stop perfPerformance Moni

Página 48

unbind portalDescription Unbinds an iSCSI portal from a portal group, or from all portal groups if noportal group alias name is given.Syntax unbind po

Página 49 - CLI> delete ip 10.0.8.224

unbind portal_groupDescription Unbinds an iSCSI portal group from its iSCSI target.Syntax unbind portal_group <pgroup>Operands <pgroup>The

Página 50

unbind unitDescription Removes the mapping of a logical unit to a LUN on an iSCSI target. Afterthe LUN is unmapped, iSCSI initiators cannot access the

Página 51

14 4Command reference

Página 52

A Storage overview• Arrays and logical drives• Fault-tolerance levels• Comparison of RAID Methods•ChoosingaRAIDlevelArrays and logical drivesThe capac

Página 53 - CLI> delete r

S1S2S3S4B1B4B7B2B5B8B11B10 B12D2D1 D3B6B3B915312Figure3Datastriping(S1-S4)anddatablocks(B1-B12)onmultiplephysicaldrives(D1, D2, D3)For data in the log

Página 54

that was originally on the failed drive to the online spare. The system is quickly restored to full RAID-leveldata protection. (In the unlikely event

Página 55

S1S2S1S2D1D5B5B1B1B5D2D6B6B2B2B6D3D7B7B3B3B7D4D8B8B4B4B815315Figure 6 RAID 1+0 array, with eight physical hard drives (D1 through D8)In each mirrored

Página 56

Table 5 RAID 5 featuresAdvantages DisadvantagesHigh read performance. Relatively low write performance.No loss of data if one physical drive fails.Los

Página 57

1. Ensure that the Telnet interface is enabled. To enable Telnet, use the SMU. For more information, seethe HP Storage Management Utility user guide.2

Página 58

Table 7 Summary of RAID methodsRAID 0 RAID 1+0RAID 5 RAID 6Alternative nameStriping MirroringDistributed DataGuarding (DDG)Advanced DataGuarding (ADG)

Página 59

IndexAAccess Control List (ACL)See ACLaccess controls, set on or offset acl,77access controls, turn onacl_entry,28ACLdelete an entrydelete acl_entry,4

Página 60

reset certificate,74reset controller,75reset management_login,76set acl,77set auto_path_change,78dual-controller system,78set certificate,79set discover

Página 61

Ffault tolerancedescription of levels,146fault tolerance (See RAID methods.),146firmwareconfigurationsdual-controller,64obtaining,61update,59downloads f

Página 62

LUNs, display current pathshow preferred_path,125LUNs, migratingmigrate unit,71Mmanagement interface network service,configureset service,94management

Página 63

2. Open your terminal emulation software. The following instructions demonstrate using HyperTerminal:a. Click StartRun to open the Run dialog box. Typ

Página 64

• Commandsarenotcasesensitiveandmustbetypedinfull.• The CLI does not support line-continuation characters. If all characters of a command cannotfit on

Página 65

18CLI setup and overview

Página 66

2 Initial configuration sequenceTheMSAcanbecompletelyconfiguredusingtheCLI.IfyouwanttousetheHPStorageManagementUnit (SMU), but the factory default manag

Página 67

Legal and notice information© Copyright 2005, 2008 Hewlett-Packard Development Company, L.P.Confidential computer software. Valid license from HP requi

Página 68

2. Configure a logical drive on a set of disks using the add unit command:CLI> add unit 0 raid_level=5 data=disk101-disk105 size=100gbLogical Unit s

Página 69

10. Use the bind portal_group to bind the portal group to the iSCSI target just created:CLI> bind portal_group pg1 target1The portal group was boun

Página 70 - CLI> locat

Configuring Access Controls for LUN accessNOTE:The steps in this section assume that you already have a basic iSCSI setup configured.1. Use the set acl

Página 71

iSNS enabled• To manually add iSNS serversa. Use the set isns command to change the iSNS server discovery mode:CLI> set isns server_discovery=manua

Página 72

4. [Optional] If required, enable access to the CLI via Telnet (not recommended) using the set servicecommand:CLI> set service telnet onCAUTION:The

Página 73 - Refreshed the iSNS entries

3 Command referenceCommand overviewTheCLIusesthefollowingbasictypesofcommands:addCreates new configuration elements.bindCreates associations between iS

Página 74

Alphabetical listing of commandsThe following MSA1510i CLI commands are included in this section:nlaccept unit, page 27set preferred_path, page 92add

Página 75 - CLI> reset controller 10

accept unitDescription Changes the state of the unit back to VOLUME_OK. Use this command toaccept media exchange on a unit previously marked as failed

Página 76

add acl_entryDescription Grants an initiator access to an iSCSI target or specificLUN.Ifyouspecifythe mapped LUN alias, the initiator is granted access

Página 77

add arpDescription Adds a static ARP entry to ARP table of the storage ports. This is generallyused only for debugging purposes.Syntax add arp <ip

Página 78

ContentsAboutthisguide ... 9Intendedaudience... 9Relateddocumentation...

Página 79

add initiatorDescription Adds an iSCSIinitiator entry to the initiator pool.Syntax add initiator <name> [alias=<alias>]> [profile=<p

Página 80 - SLP enabled

add ipDescription Assigns an IP address to the specified storage port.Syntax add ip <port><ip[/<mask>]> [<vlan>]Operands <po

Página 81

add isns_serverDescription Adds an iSNS server to the iSNS server pool.NOTE:iSNS servers can be added with this command only when the iSNSserver disco

Página 82

add portalDescription Adds a new portal entry in the portal pool. To use the portal, it must bebound to a portal group using the bind portal command.S

Página 83

add portal_groupDescription Adds a new portal group entry into the portal group pool. To use the portalgroup, it must be bound to a target using the b

Página 84

add routeDescription Adds a static route to a controller. This command is generally used fordebugging purposes.NOTE:There is one routing table per con

Página 85

add spareDescription Causes the specifieddriveordrivestobeusedasasparebythespecifiedunit.Syntax add spare unit=<unit_number><diskrange>Opera

Página 86 - • Canonical iSCSI target

add targetDescription Adds a new target to the target pool. The target name must be world wideunique. If all target elements are already configured (al

Página 87

add unitDescription Adds a new LUN comprised of one or more hard drives.NOTE:Maintain a record of the units as they are created. These Unit ID numbers

Página 88

[Optional]Thestripesizetoassign(inKB).Validvaluesare8,16,32,64, 128, or 256 Kilobytes.• RAID0usesstripesizes8,16,32,64,128,and256.Default:128KB.• RAID

Página 89

bindunit... 44clearperf... 45deleteacl_entry...

Página 90

Example 2To assign multiple LUNs from a drive or group of drives, use the add unit command and includethe size= command option. Repeat the command usi

Página 91 - The operation was successful

newpage pi1510i Modular Smart Array Command Line Interface user guide41

Página 92

bind portalDescription Binds an iSCSIportal to a portal group. This allows initiators to access theiSCSI target to which the portal group is bound.Syn

Página 93 - MSA-1>

bind portal_groupDescription Binds an iSCSI portal group to an iSCSI target, allowing any portals in theportal group to be used to access the target.

Página 94

bind unitDescription Binds a logical unit to a LUN on an iSCSI target. A unit can only be boundto one target. The LUN number is seen by iSCSI initiato

Página 95 - SNMP parameters set

clear perfDescription Resets the controller performance analysis data previously initiated withthe start perfcommand.Syntaxclear perfOperands NoneExam

Página 96

delete acl_entryDescription Deletes an entry from the Access Control List (ACL), removing initiatorpermission to access to an iSCSI target or specificL

Página 97

delete arpDescription Deletes an entry from the ARP table. Each physical port has its own ARPtable.NOTE:Only static ARP entries added with the add arp

Página 98

delete initiatorDescription Removes an initiator entry from the initiator pool.NOTE:If Access Control is disabled, the initiator can still access iSCS

Página 99

delete ipDescription Deletes an IP address and all associated iSCSI portals.Syntax delete ip <IP ad dress>Operands <IP address>The IP addr

Página 100 - Command reference

showisns... 116showisns_server... 117showmanagement...

Página 101

delete isns_serverDescription Deletes an iSNS server.Syntax delete isns_server <iSNS server alias>Operands <iSNS server alias>The alias na

Página 102

delete portalDescription Delete an iSCSI portal and removes associations to the portal group and IPconfigurationtable.Syntax delete portal <portal a

Página 103

delete portal_groupDescription Deletes an iSCSI portal group. Any portals in the portal group areautomatically unbound.Syntax delete portal_group <

Página 104

delete routeDescription Deletes the specifiedrouteentryfromtheroutingtableforthespecifiedcontroller.Syntax delete route <ctlr><ip[/<mask>

Página 105

delete spareDescription Causes the specifieddrivetonolongerbeusedasasparebythespecifiedunit.Syntax delete spare unit=<unit><diskrange>Operan

Página 106

delete targetDescription Removes the target from the target pool. All associated portal groups areautomatically unbound.Syntax delete target<target

Página 107

delete unitDescription Deletes the LUN or LUNs. All resources used by, and settings associatedwith the unit are deleted.NOTE:After a LUN is deleted, i

Página 108

• extend unit• migrate unit• set unit_id• show unit_id• unbind unitnewpage pi1510i Modular Smart Array Command Line Interface user guide57

Página 109

disable this_controller|other_controllerDescription In a dual-controller system, this command disables one of the controllers toprepare it for removal

Página 110 - Not provided

download firmwareDescription Updates firmware on the MSA1510i controller or MSA1510i othercomponents, or, updates fi rmware on the hard drive storage enc

Página 111

Figures1Multiplephysicaldrives(D1,D2,andD3)inasystem ... 1452Multiple physical drives (D1, D2, and D3) configured into one logical drive (

Página 112

• When determining which MSA controller firmware version to use, review the requirements andinformation in the Compatibility Matrix(es), release notes,

Página 113

1. Determine which version firmware is currently installed on the MSA by using one of the followingmethods:• With the array controller powered on, pres

Página 114

7. Establish a serial connection to the CLI using an emulator program such as HyperTerminal.NOTE:the following example describes the HyperTerminal emu

Página 115

9. On the menu bar at the top of the emulator window, select Transfer > Send File.10. In the Send File window:a. Click Browse, navigate to the dire

Página 116

12. Restart the MSA and its attached storage enclosures storage system by doing the following (newlydownloaded firmware cannot be accessed until the MS

Página 117

expand unitDescription Adds a physical drive or drives to the LUN. This enables the specified unitand all units on the same volume to utilize more disk

Página 118

extend unitDescription Adds unused, available space in an array to the specified LUN.Syntax extend unit <unit><sizing option>Operands <u

Página 119

helpDescription Displays helpful information about CLI commands. Displayed informationmay include a brief definition, required command syntax, availabl

Página 120

controller adu_page mib2drive_report perf cacheinfotaskstats debug eventlogaculockSpecify command word:Example help display all command and responseCL

Página 121

show perf start perfstop perf clear perfshow cacheinfo show taskstatsset debug show eventlogExample help add unit command and responseCLI> help add

Página 122

Tables1Documentconventions... 102CLIspecialkeys ... 163RAID0features ...

Página 123

locateDescription Helps you locate specific hardware by flashing the LEDs of the drives in therequested hardware. These LEDs are visible from the front

Página 124

migrate unitDescription Migrates an existing LUN from one RAID level to another. If you attempt tomove to an unsupported RAID configuration for a LUN,

Página 125

• show unit• set unit• accept unit• expand unit• extend unit• set unit_id• show unit_id• unbind unitnewpage pi72Command reference

Página 126

refresh isns_entriesDescription Re-registers all iSNS-enabled targets with all iSNS servers.Syntaxrefresh isns_entriesOperands NoneExampleCLI> refr

Página 127

reset certificateDescription Removes the SSL certificate being used by the management interface andresets the system to using an internally-generated, s

Página 128

reset controllerDescription Restarts the MSA controller through which you are connecting to the CLI.During this process, detailed progress and status

Página 129

reset management_loginDescription Resets the management username and password to their factory defaults.This command is only available through the ser

Página 130

set aclDescription Sets access controls on or off for an iSCSI target.NOTE:When set acl disable is entered, all existing ACL entries on thetarget are

Página 131

set auto_path_changeDescription for dual-controller configurations only, turns on or off automatic, MSA-basedI/O load balancing. If automatic path chan

Página 132

set certificateDescription Sets the SSL certificate to be used by the management interface. This isused to load a real certificate in place of the defaul

Página 134

set discoveryDescription Enables or disables SLP and iSNS discovery on an iSCSI target.Syntax set discovery <target> [slp=enable|disable][isns=e

Página 135

set globalsDescription Sets the expand priority, the read/write ratio, or the system name,depending on the parameters specified.NOTE:All operands are o

Página 136

[Optional] The write cache as a percentage of the total cache. The valueof <w> must be between 0 and 100, and the sum of the read cache andwrite

Página 137

set initiatorDescription Sets the profile (operating system) associated with the initiator. If the profileis not set for an initiator, a default profile

Página 138

set initiator_chapDescription Sets the CHAP secret (password) for an iSCSI initiator in mutual CHAPauthentication.Syntax set initiator_chap <initia

Página 139 - Performance Monitor started

set iscsi_keysDescription Sets iSCSI login parameter keys for an iSCSI target.Syntax set iscsi_keys <target>[<parameter>=<setting>]N

Página 140 - Performance Monitor stopped

Example 1CLI> set iscsi_keys target1 authentication=chapThe new values were set successfully.Example 2CLI> set iscsi_keys target1 defaultThe new

Página 141

set isnsDescription Sets the iSNS parameters.Syntaxset isns [service=enable|disable] [server_discov-ery=manual|dhcp|slp] [esi=<esi_port>] [entit

Página 142

set managementDescription Sets global management interface settings for the system.Syntax set management [disable|enable] [port=<port>][dhcp=<

Página 143 - LUN lun2t1 has been unmapped

gateway=<ip>The IP address, in doted notation.dns1=<ip>The IP address, in doted notation.dns2=<ip>The IP address, in doted notation.

Página 144

About this guideThis document provides information to help you use the HP StorageWorks 1510i Modular Smart Array(MSA1510i) Command Line Interface (CLI

Página 145 - A Storage overview

set management_loginDescription Configures thelogin and password used to access the managementinterface. The command prompts you to enter your old user

Página 146 - Fault-tolerance levels

set portDescription Enables or disables a physical port.NOTE:By default, allportsareenabled.Syntax set port <port> enable|disableOperands <po

Página 147 - RAID 1+0—drive mirroring

set preferred_pathDescription For dual-controller configurations only, this command either sets thecontrollerownership(path)forthespecified LUNs, or, re

Página 148

set promptDescription Changes the CLI prompt from the default of CLI>.Syntax set prompt <new_prompt>Operands <new_prompt>The text to us

Página 149 - RAID 6—advanced data guarding

set serviceDescription Configures the management interface network services.Syntax set service <service-name> enable|disable port=<port-number

Página 150 - Choosing a RAID level

set snmpDescription Configures the settings for the embedded SNMP agent.NOTE:Although all parameters are optional, at least one parameter must besuppli

Página 151

set target_chapDescription Sets the CHAP secret (password) used to access an iSCSI target whenCHAP is enabled. To enable CHAP authentication on the ta

Página 152

set this_controller|other_controllerDescription Sets the baud rate for the CLI serial port on the specified controller.NOTE:When using this command, yo

Página 153

set this_controller_id|other_controller_idDescription Assigns a name or identifier to the controller.Syntax set this_controller_id <identifier>ors

Página 154

set unitDescription Enables or disables the array accelerator cache for a specificLUN.Syntax set unit <unit> cache=enable|disableOperands <uni