Hp XP Performance Advisor Software Manual do Utilizador Página 184

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 183
The following table describes the CHIP/CHA summary table for an XP disk array and the CHA
summary table for a P9000 disk array.
CHA summary table for P9000 disk arrays includes...CHIP/CHA summary table for XP disk arrays includes...
The CHA nameThe CHIP or the CHA name
Example: CHA-1F, 1 indicates the cluster # where the CHA
board is located.
Example: CHA-1EU
Not applicableThe individual MPs and their utilization percentage
In the above image, XX in CHPXX-IEU indicates the
corresponding MP ID, which can be 00, 01, 02, or 03. The
CHPXX-IEU utilization % indicates the MP utilization percentage,
which is as follows:
CHP00-1EU is 7%
CHP01-1EU is 2%
CHP02-1EU is 33%
CHP03-1EU is 2%
Not applicableThe MP to port mapping data, where the associated port IDs
appear in the respective MP utilization blocks.
In the above image, the MP- port mapping for the CHIP,
CHA-1EU is as follows:
CHP00-1EU - associated ports are CL1A and CL5A
CHP01-1EU - associated ports are CL3A and CL7A
CHP02-1EU - associated ports are CL1B and CL5B
CHP03-1EU - associated ports are CL3B and CL7B
The average port activity (I/Os and MB/s) of all the associated
ports in the Port Activity Avg block.
The average port activity (I/Os and MB/s) of all the associated
ports in the Port Activity Avg block.
In the above image, the average port I/Os is 2739.00 and the
average port MB/s is 170.95.
In the above image, the average port I/Os is 7389.40 and the
average port MB/s is 57.73.
184 Viewing XP and P9000 disk array components
Vista de página 183
1 2 ... 179 180 181 182 183 184 185 186 187 188 189 ... 415 416

Comentários a estes Manuais

Sem comentários