The following table shows the priority of pool-VOLs with system area when creating pools.
Data drive typePriority
SAS7 2K1
SAS10K2
SAS15K3
SSD4
External volume5
If more than one pool-VOL of the same data drive type exists in the storage system, the pool-VOLs
priority is determined according to the storage system’s internal index information.
Related topics
“Fast Snap volume requirements (page 29)
Workflow for registering virtual volumes
Use the following workflow to register virtual volumes:
1. (Optional) Edit the SSID of the V-VOL you want to register to the pool-VOL’s paired volume
(see “Editing the SSID for virtual volumes (page 42)).
2. (Optional) Change the V-VOL settings (see “Changing LDEV settings (page 44)).
3. Register the V-VOL (see “Creating LDEVs (page 51)).
Editing the SSID for virtual volumes
Before registering a V-VOL, you may need to edit the control unit’s (CU) SSID, which you use to
create new LDEVs. Use the Change SSIDs window to edit a V-VOL’s SSID.
Prerequisite: The SSID must be newly allocated (SSID Changeable status is Yes.)
For more information about registering V-VOLs, see “Creating LDEVs (page 51).
1. In the RWC main window, in the resource tree in the Explorer, click Pools.
2. In the Pools window, in the Pools tab, click Create LDEVs.
42 Configuring Fast Snap