HP StorageWorks
Enterprise Virtual Arr ay 3000/5000 user
guide (VCS 3.110)
ThisuserguidecontainsconceptualandproceduralinformationabouttheHPStorageWorksEnterpriseVirtualArray
and its online interface.
Part number: 5697-6377
E
leventh edition: April 2007
Vista de página 0
1 2 3 4 5 6 ... 187 188

Resumo do Conteúdo

Página 1 - HP StorageWorks

HP StorageWorksEnterprise Virtual Arr ay 3000/5000 userguide (VCS 3.110)ThisuserguidecontainsconceptualandproceduralinformationabouttheHPStorageWorksE

Página 2

39..Enclosure address bus components with shelf ID expansion cables . . . . . . . . . . . 8440..TypicaloperationalLEDstatusdisplays—enclosurefront ...

Página 3 - Contents

CAUTION:IfyoudecideNOTtoPowerOffwhileworkinginthePowerOffmenu,thePowerOffSystemNOoptionmust be displayed before you press the ESC () push-button to av

Página 4

5. Press to select POWER OFF SYSTEM.6. Pressto accept NO.Pressto scroll to POWER OFF SYSTEM YES.7. Pressto accept YES.Pressto select NO.Uninitializing

Página 5

Password optionsThe passw ord entry options are:• Enteringapasswordduringstoragesysteminitialization(seeSetting Up an HSV110-SeriesControllerPairUsing

Página 6

Clearing a passwordUse the following procedure to remove storage system password protection.NOTE:Changing a system password on the controller requires

Página 7

NOTE:In Figure 48, the connectors are identified by the label printed on the controller. The numbered itemcaptions defi ne the connector function.CXO804

Página 8

For more information about racks and configurations, including expansion and interconnection, refer tothe HP StorageWorks Enterprise Virtual Array Hard

Página 9

• Thestandard50-HzPDUcablehasanIEC309,3-wire,30-A,50-Hzconnector.• The standard 60-Hz PDU cable has a NEM A L6-30P, 3-wire, 30-A, 60-Hz connector.If t

Página 10

CXO7571A1 726 11123 4 51098Figure 51 Du al PDU assembly major com po nents1. PDU 12. PDU 1 receptacle A3. PDU 1 receptacle B4. PDU 1 receptacle C5. PD

Página 11

11320040aFigure 52 228481–002/22481–003 PDU ass emb ly1. mounting brackets2. cord retention brackets3. grounding cablesPDMsThere are eight PDMs mounte

Página 12

CXO7568B123Figure 53 Rack PDM1. Power receptacles2. Thermal circuit breakers3. IEC309 AC power connector252638–001 PDM modelThe 339388–001 PDM mountin

Página 13 - About t his guide

Tables1..Documentconventions ... 142..FailbackPreferenceSettings... 463..Failback SettingsbyOperatin

Página 14 - Conv entions

0038a11Figure 54 Rack-mounted 252638–001 PDM1. PDM mounting brackets, right-side orientation.Rack AC power distributionThe power distribution in an En

Página 15 - Getting help

CXO8237A12345678910Figure 55 Rack AC power distribution1. PDM 42. PDM 33. PDM 24. PDM 15. PDU 16. PDU 87. PDM 78. PDM 69. PDM 510. PDU 2Rack System/E

Página 16 - HP authorized reseller

ThesiteACinputvoltageisroutedtoeachPDUmountedintherack.EachPDUdistributesACthroughten receptacles directly to the storage system components.• PDUs 1 a

Página 17 - 1 System description

CXO8238A1324 56782Figure 56 10000-Series single rack configura tion floo r space requirements1. Front door2. Rear door3. Rack width 600 mm4. Service are

Página 18 - Virtualiz ation

12CXO7589AFigure 57 Raising a leveler foot1. Hex nut2. Leveler foot3. Carefully move the rack to the installation area and position it to provide the

Página 19 - Storage system components

A Regulatory noti ces an dspec ificationsThis section p rovides regulatory notices and specifications for the various components of the EnterpriseVirtua

Página 20 - Command View EVA

Class B equipmentThis equipm ent has b een tested and found to comply with the limits for a Class B digital device, pursuantto Part 15 of the FCC Rule

Página 21 - Virtual controller software

WARNING!WARNING: To reduce the risk of exposure to hazardous radiation:• Do not try to open the laser device enclosure. There are no user-serviceable

Página 22 - Hardware

• EN55022 (CISPR 22) - Electromagnetic Interference• EN55024(IEC61000-4-2,3,4,5,6,8,11)-ElectromagneticImmunity• EN61000-3-2 (IEC61000-3-2) - Power Li

Página 23

Estonian noticeSeadmete jtmetekrvaldamine eramajapidamistes Euroopa LiidusSee tootel vi selle pakendil olev smbol nitab, et knealust toodet ei tohi ko

Página 24 - Fibre Channel loop switches

38..Fibre Channel switch specifications... 12939..Controller enclosure physical specifications ... 12940..Controll

Página 25 - EVA5000 HSV110 controllers

Το σύµβολο αυτό στο προϊόν ή τη συσκευασία του υποδεικνύει ότι το συγκεκριµένο προϊόν δενπρέπει να διατίθεται µαζί µε τα άλλα οικιακά σας απορρίµµατα.

Página 26 - EVA3000 HSV100 controllers

is simbolis ant gaminio arba jo pakuot?s rodo, kad io gaminio alinti kartu su kitomis nam? ?kioatliekomis negalima. alintinas ?rangos atliekas privalo

Página 27

Ta znak na izdelku ali njegovi embalai pomeni, da izdelka ne smete odvre?i med gospodinjskeodpadke. Nasprotno, odslueno opremo morate predati na zbira

Página 28 - System description

Japanese noticeHarmonics conformance (Japan)Taiwanese noticeJapanesepower cord noticeCountry-specificcertificationsHP tests electronic products for comp

Página 29 - SAN considerati

Figure 58 Typical enclosure certification la b elNOTE:The certification symbols on the label depend upon the certification level. For example, the FCC Cl

Página 30

CAUTION:An assembled enclosure (all elements installed) weighs more than 65 lbs (29.5 kg) and requires aminimum of two individuals to move.Table 30 de

Página 31 - 2 Startup and operation

Table 31 Drive en c l osure elements physical s pecificationsSpecificationInstalled Shipping CartonEnvironmental Monitoring Unit (EMU)Height114mm(4.5in)

Página 32 - Startup and operation

Table 32 Environmental operating specificationsAmbient temperature : +10°Cto+35°C(+50°Fto+95°F)withanaveragerateofchangeof1°C/hourmaximumandastepchange

Página 33 - Gathering Info

Table 35 AC input current and wattageNominalMaximumInput VoltageAmps Watts Amps Watts60–Hz Input100 VAC–JBOD 4.35 436 6.41 641208 VAC–NorthAmerica2.03

Página 34 - Behavior

Fibre Channel switch specificationsThe Fibre Channel Switch requires a clean, dry environment for normal operation. Table 38 lists thespecifications for

Página 35

About t his guideThis user guide provides information to help you:• Learn about the HP StorageWorks Enterprise Virtual Array and its components.• Star

Página 36 - Obtaining a license key

Table 41 AC input current and wattageNominalMaximumInput voltageAmps Watts Amps Watts60-Hz Input100 VAC–JBO D 4.35 436 6.41 641208 VAC–North America2.

Página 37 - Entering data using the OCP

Table 43 9000-Series En terpris e 42U Rack Physical DimensionsConfiguration Height in / mm Width in / mm Depth in / mm Max Wt lbs / kgEnterprise 2C6D7

Página 38

Table 48 10000-Series Enterprise 42U Rack Shipping DimensionsConfigurations H eight in / mm Width in / mm Depth in / mmMax Wt(packaging)lbs / kgEnterpr

Página 39

Table 51 Enterprise Virtual Array AC power specificationsNominal input voltageSpecifications60-Hz Service202 VAC Voltage Range PowerReceptacleJapan 180-

Página 40 - Installing Command View EVA

13 4Regulatory notices and specifications

Página 41

B EMU gen e ra ted condition reportsThis section provides a description of the EM U generated condition reports that contain the followinginformation:

Página 42

Table 52 Assigned element type codesCode Element0.1.Disk Drives (see Drive Conditions)0.2.Power Supplies (see Figure 30)0.3.Blowers (see Figure 30 )0.

Página 43

• If the EMU determines the drive cannot operate at the Fibre Channel link rate set by the I/Omodule, the drive bypass function ends and the drive is

Página 44

This error remains active u ntil the problem is corrected.Complete the following procedure to correct this problem:1. Record all six characters of the

Página 45 - 3 Enterprise Virtu al Array

CXO7952A21Figure 60 Po w er supply element numberingThe following sections define the power supply condition reports.0.2.en.01 NONCRITICAL Condition—Po

Página 46

Conv entionsConventions consist of the following:•DocumentConventions•TextSymbols• Equipment SymbolsDocument conventionsThe document c onventions incl

Página 47

1. Record all six characters of the condition report.2. Ensure that the blower on the power supply is functioning properly. If not, correct the blower

Página 48

To correct this problem, record all six characters of the condition report, then contact your authorizedservice representativ e.0.3.en.03 UNRECOVERABL

Página 49 - Storage system s

• en. is the two-character temperature sensor element• ec is the error co d eRefer to Table 53 to determine the location of each temperatur e sensor.T

Página 50

4. Ensu re that both blowers are operating properly (the L EDs are on) and neither blower is operatingat high speed.5. Verify that the ambient tempera

Página 51

4. If Steps 1, 2 or 3 did not reveal a problem, use Command View EVA to request the HSV110 controllerto shut down the drive enclosure. Completing this

Página 52 - Adding disk driv

3. O bserve the EMU to ensure the error is corrected.4. If resetting the EMU did not c orrect the problem, replace the EMU.5. If unable to correct the

Página 53 - Creating disk groups

0.7.01.11 NONCRITICAL condition—EMU NVRAM write failureThe EMU cannot write data to the NVRAM. This condition report remains active until the problem

Página 54 - Adding a disk driv e

5. Observe the EMU to ensure the error is corrected.6. Reset the EMU, then obser ve the EMU to ensure the error is corrected.7. If resetting the EMU d

Página 55 - Checking status indicators

1. Record all six characters of the condition report.2. Reset the EMU.3. Observe the EMU to ensure the error does not recur within the fi rst minute.4.

Página 56 - Handling fiber optic cables

0.F.en.02 CRITICAL Condition—Transceiver Data Signal LostThis symptom can occur when a controller has been powered off or a cable has been removed fro

Página 57

Any enclosed surface or area of the equipm ent marked with these symbols indicates the presence ofelectrical shock h azards. Enclosed area contains no

Página 58

Table 54 Voltage and Current Sensor LocationsSensorSensor Elem ent Location01.Power Supply 1 +5VDC02.Power Supply 1 +1 2 VDC03.Power Supply 2 +5 VDC04

Página 59 - 4 Storage system hardwa re

To correct this problem, record all six characters of the condition report, then contact your HP authorizedservice representativ e.Backplane condition

Página 60 - /O modules

CXO7951A12Figure 64 I/O module element numbering1. I/O Module A (01)2. I/O Module B (02)Correction of an I/O module problem normally requires replacin

Página 61 - CXO7420A

8.7.en.12 NONCRITICAL condition—I/O Module NVRAM read failureThe system is unable to read data from the I/O module NVR A M.Complete the following proc

Página 62 - I/O module status displays

154EMU generated condition reports

Página 63 - I/O module power

C C ontroller fault managementThis appendix describes how the controller displays events and termination event information. Terminationevent informati

Página 64 - Copper Fibre Channel cables

GUI event displayA problem that g enerates the Event display reduces the system capabilities. You can use the informationin this display (see Figure 6

Página 65 - Fibre Channel disk d rives

Displaying Detailed InformationThe Detail View menu lets you examine detailed fault information stored in the Last Termination EventArray (LTEA). This

Página 66 - Drive status displays

Tab l e 55 C ontroller Event Text Descr ip t ion FileInformation TypeDescriptionEvent CodeThis hexadecimal code identifies the reported event type.Term

Página 67 - Drive blank

D Cus tomer repl aceabl e unitsThis appendix describes the procedures for replacing CRUs. Information about initial enclosureinstallation, ESD protect

Página 68 - Power and cooling components

NOTE:For c ontinuous quality improvement, calls may be recorded or monitored.Be sure to have the following information available before calling:• Tech

Página 69 - Temperature sensing

Determining CRU part numbersAll elements havea6–3sparepartnumberontheproductlabel(seeFigure 6 7). This nine-characternumber appearsimmediately below t

Página 70 - Drive enclosure EMU

CXO6826A12Figure 68 Removing a drive2. Pull on the drive until it disconnects from the backplane connector.CAUTION:The carrier ca n be dropped due to

Página 71 - Controls and displays

NOTE:If one or more of the disk drives inserted does not reach the solid green indication after70 seconds, remove the drive or drives and check for da

Página 72 - EMU monitoring functions

CXO7359B ˚12Figure 70 Installing and removing a drive blankNOTE:When installing drives, start at slot one, and do not leave blank slots between drive

Página 73 - EMU LED displays

• When to Clean —If a connector may be contam ina ted, or if a connector has not been protectedby a dust cover for an extended period of time, clean i

Página 74

GlossaryThis glossary defi nes terms used in this guide or related to this product and is not a comprehensiveglossary of computer terms.µm A symbol for

Página 75

array controller See controller.asynchronous Events scheduled as the result of a signal requesting the event or that which iswithout any specified time

Página 76

cache battery in-dicator1. An orange light emitting diode (indicator) that illuminates on the controlleroperator control panel (OCP) to define the stat

Página 77 - Audible alarm operations

data entry mode The state in which controller information can be displayed or controllerconfiguration data can be entered. On the Enterprise Storage Sy

Página 78 - Enabling the audible alar m

dual power supplyconfigurationSee redundant power configuration.dynamic capacit yexpansionA storage system feature that provides the ability to increase

Página 79 - Disabling the audible alarm

1 System descriptionThis chapter provides an overview of the Enterprise Virtual Array and its components.IntroductionThe HP StorageWorks Enterprise Vi

Página 80

Enclosure ServicesInterfaceSee ESI.Enclosure ServicesProcessorSee ESP.Enterprise VirtualArrayThe Enterprise Virtual Array is a product that consists o

Página 81

Fault Manage-ment CodeSee FMC.Fibre Chann eldrive enc losureFibre Channel Arbitrated Loop. The American National Standards Institute’s(ANSI) document

Página 82

Gb Gigabit. A m easurement of the rate at which the transfer of bits of dataoccurs. Sometimes referred to as Gbps. Nominally, a Gb is a transfer rate

Página 83

I/O modul e Input/Output modu le. The enclosure element that is the Fibre Channel driveenclosure interface to the host or controller. I/O modules are

Página 84

logon Also called login, it is a procedure whereby a user or network connection isidentified as being an authorized network user or participant.loop Se

Página 85 - Using the condi

multi-mode fiber A fiber optic cable with a diameter large enough (50 microns or more) to allowmultiple streams of light to travel different paths from

Página 86

PDU Power Distribution Unit. The rack device that distributes conditioned AC or DCpower within a rack.petabyte A unit of storage capacity that is the

Página 87 - Navigating the error display

read aheadcachingA cache m anag ement method used to decrease the subsystem response time toa read request by allowing the controller to satisfy the r

Página 88

small computersystem interfaceSee SCSI.Snapclone A virtual disk that can be manipulated while the data is being copied. Only anActive m em ber of a vi

Página 89 - Verifying enclosure operation

may be incapable of recovering or bypassing the failure and will require repairsto correct the condition.This is the highest level condition and has p

Página 90 - Status monitoring and display

• Virtualization technology, Vraid, enables data to be distributed from 8 to 240 disks to increasedisk spindle count far beyond traditional RAID sets.

Página 91

write backcachingA controller process that notifi esthehostthatthewriteoperationiscompletewhen the data is written to the cache. This o ccurs before tr

Página 92 - Reading the switch LEDs

In dexSymbols+5.1 VDC ,692C12D configuration,1741 U ra c k ,17,27AAC input missing,139AC powerdistributing,105frequency,69voltage,69AC power specificati

Página 93 - HSV controllers

CAUTIONsair flow,65disk drives,65,68CDRH, compliance regula tions,117Center for Devices and Radiological HealthSee CDRHcertification product labels,123c

Página 94 - Operator control panel

disk drivescompatibility,160adding,52CAUTIONs about,65,68connecting to backplane,162defined,65disconnecting from backplane,161displaying status,90hot s

Página 95 - Navigation push-buttons

environmental specificationsair quality,127,132altitude,127controllers,130Fibre Channel Loop Switches,129relative humidity,127,132shipping,132short ter

Página 96

iconsbattery status,95pushbuttons,95IDX code display,156INFORMATION conditions,86audible alarm,77defined,86drive missing,137EMU,145,147INITIALIZE LCD,9

Página 97 - Displaying system information

OOCPfault m anagement displays,156firmware version,98using,37OCPpushbutton icons,103online help system,20,21OpenView Storage Management Appliance,20, 4

Página 98 - Displaying Vers

regulatory notices,115relative humiditydrive enclosure,127short term storage,127drive enclosure,127operating,132shipping,127,132short term storage,132

Página 99 - Shutting down the system

temperaturecondition reports,141effect of air flow,69sensing,69,90T ermination CodeSee TCtermination event GUI display,155thermal protection, power sup

Página 100 - Powering off the system

virtual disk capacity and redundancy levels. All of this work is done from a c entral loca tion—CommandView EVA. See the Command View EVA online help

Página 101 - Uninitializ

Legal and notice information© Copyright 2003-2007 Hewlett-Packard Development Company, L.P.Hewlett-Packard Company makes no warranty of any kind with

Página 102 - Changing a password

CommandView EVAHostHost HostBrowserAdministratorControl andMonitorCommandsControl InputMonitoring OutputCXO8058AStorageSystemFabricVCSData DataDataFig

Página 103 - HSV controller cabling

• Content p ane—located on the right side of the window, below the Session pane. It is the largestwindow and is where most administrative tasks are pe

Página 104 - Rack configurations

VCS benefitsVCS provides scalable capacity on-demand, helps improve per formance, increases disk utilizationefficiency, a nd allows for easy dynamic sto

Página 105 - Power distribution

• Fibre Channel drive enclosure—Holds disk drives, power supplies, blowers,Input/Output(I/O)modules, transceivers, and an Environmental Monitoring Uni

Página 106

Each hardware component is identified in the following sections and is descr ibed in detail in StorageSystem Hardware Components.Fibre Channel drive en

Página 107

FrontBezelCXO8242AFigure 6 FC loop switch—bezel and front viewNOTE:Each bezel covers two FC loop switches in a space capacity of 1U. One "U"

Página 108

CXO7943ACXO7944BFigure 7 H SV110 controller location—front and rear viewsEVA3000 HSV100 controllersThe HSV10 0 controllers serve as the interface betw

Página 109

CXO8054BFrontRearFigure8HSV100controller—frontandrearviewsRackThe rack provides the capabilit y for mounting standard 483mm (19in) wide controller and

Página 110 - Rack AC power distribution

• Power Distribution Units (PDUs)Figure 9 shows the 42U rack.Rear42UCXO7945BFrontFigure 9 42U rackHostsandtheEnterpriseVirtualArrayThis section descri

Página 111 - CXO8237A

SAN considerationsEnsure that your SAN c omponents are all supported for use with the Enterprise Virtual Array.Design your SAN with an HP standard top

Página 112 - Moving and stabilizing a rack

ContentsAboutthisguide ... 13Overview... 13Intendedaudience...

Página 113

30System description

Página 114

2 Startup and operationThis chapter provides the procedures necessary to continue installation and startup of your EnterpriseVirtualArray.Pleasecontac

Página 115 - A Regulatory noti ces an d

BrowserHost XFCAStorageManagementApplianceCommandView EVACXO8099BControllerAFCA FCA FCAHost ZBrowserNon-HostFP1 FP2LoopPair 1LoopPair 2LoopPair 1LoopP

Página 116 - Laser device

7. Make virtual disks available to their hosts. Refer to the storage system software documentation foreach host’s operating system.Gathering Informati

Página 117 - European union notice

Table 2 Failback Preference SettingsSetting Point in timeBehaviorAt initial presentationTheunitsarealternately b rought onlineto ControllerA or to Con

Página 118 - WEEE Recycling Notices

Setting Point in timeBehaviorAt initial presentation The units are brought online to ControllerA.On dual boot or controller resynchIf cache data foraL

Página 119 - Greek notice

Changing virtual disk failover/failback settingChangi ng the failover/failback setting of a virtual disk may impact which controller presents the disk

Página 120 - Lithuanian notice

• Move the rack.• Stabiliz e the rack.• Inspectthestoragesystem.• Install the controller cache batteries.• Apply power.• Attach the controllers to the

Página 121

CXO7601CFigure 12 Location of the World Wide Name la be lEntering the WWNTable 5 defines the push-button functions when entering the WWN or the WWN che

Página 122 - Swedish notice

5. Press or until the first character is display ed. Press to accept this character and select thenext.6. Repeat Step 5 to enter the remaining characte

Página 123 - Country-specificcertifications

SettingupacontrollerpairusingtheOCP... 37InstallingCommandViewEVA... 40InstallingOptionalEVASoftwareLic

Página 124 - Physical specifications

2. With either of the default menus (Storage System Nam e or Node World Wide Name) displayed,press any push-button to select the menu tree.3. Pressto

Página 125

NOTE:The storage s ystem may take a long time to complete the necessary cache flush during controllershutdown when snapshots are being used. The delay

Página 126 - Environmental specifications

Figure 14 Shutdown Options page4. In the System Shutdown section of the Content pane, click Power Down to achieve the effectdescribed to the right of

Página 127 - Power specification

4. Wait three m inutes and then verify that all disk drives are ready. The drive ready indicator andthe drive online indicator should b e on (green).5

Página 128

44Startup and operation

Página 129 - Controller specifications

3 Enterprise Virtu al ArrayoperationThis chapter presents the tasks that you might need to perform during normal operation of the storagesystem.Best p

Página 130 - Environm

Table 7 Failback preference settingsSetting Point in timeBehaviorAt initial presentationTheunitsarealternately b rought onlineto ControllerA or to Con

Página 131

Setting Point in timeBehaviorAt initial presentation The units are brought online to ControllerA.On dual boot or controller resynchIf cache data foraL

Página 132 - Power specifications

Table 8 Failback S ettings by Operatin g SystemOperating systemDefault behaviorSettings supportedHP-UXAutoback done by the hostNo Preference, Path A/B

Página 133 - The power

Storage system shutdo wn and pow erupThe storage system is shut down using HP Command View EVA. The shutdown process performs thefollowing functions i

Página 134

Navigatingtheerrordisplay... 87Viewingthereportinggroupfeature ... 88Verifyingenclosureoperation ...

Página 135 - Correcting errors

NOTE:Before applying power to the rack, ensure that the power switch on each HSV controlleris off.3. Power on the circuit breakers on both EVA rack PD

Página 136 - Drive conditions

5. Enter CAPTURE CONFIGURATION , specifying the full pa th and filename of the output files forthe configuration data.The configuration data is stored in

Página 137

Adding disk drives to the storage s ystemAs your storage requirements grow , you may be adding disk drives to your storage system. Adding newdiskdrive

Página 138 - Power supply conditions

Figure 15 Disk drive activity indicatorCreating disk groupsThe new disks you add will typically be used to create new disk groups. Although you cannot

Página 139

CX8167-ST21Figure 16 Sequenti al b u ilding of vertical disk groups1. Disks in stalled in fi rst group2. DisksinstalledinsecondgroupAdding a disk driv

Página 140 - Blower conditions

Changing the Device Addition PolicyTo prevent the storage system from automatically grouping a new disk drive that may have the incorrectfirmware on it

Página 141 - Temperature conditions

• Check the following using Command View EVA.• Navigate to the disk drive and check the operational state. It s hould be.•RecordtheModel number and th

Página 142

covers or dust caps provided by the manufacturer. These covers are removed during installation, andare installed whenever the transceivers or cables a

Página 143

58Enterprise Virtual Array operation

Página 144 - EMU conditions

4 Storage system hardwa recomp on entsThis chapter describes the Enterprise hardware components.Fibre Channel drive enclosuresThedriveenclosure contai

Página 145 - 0.7.01.05 U

Finnishnotice... 119Frenchnotice ... 119Germannotice ...

Página 146 - 0.7.01.13

CXO7882AFrontRear3 41 295 76 8Figure 20 FC drive enclosure—front and rear views1. Drive bay 12. Drive bay 143. EMU4. I/O module B5. Blower 16. Power s

Página 147

CXO7421AFigure 21 I/O module BCXO7420AFigure 22 I/O module AEnterprise supports only dua l-c ontroller, dual-loop operation. Each controller is connec

Página 148 - Transceiver conditions

CXO7951A12Figure 23 I/O module locations1. I/O module A2. I/O module BThe I/O modules are major components in the Fibre Channel loop. Each module has

Página 149

Table 10 Operational I/O m odul e s tatus indicatorsTop Power BottomDescriptionsOffOnOff• I/O Module is operationalOnFlashing,then OnOn• Top port—Fibr

Página 150

• The I/O module is replaced, if defective.• The overcurrent condition no longer exists.NOTE:A disabled I/O module cannot transfer data and disconnect

Página 151 - I/O Module conditions

CXO8164AFigure 26 Copper Fibre C hannel cableFibre Channel disk d rivesThe Fibre Channel drives are hot-pluggable and include the following features:•

Página 152

Drive status reportingThreestatusindicators(seeFigure 28) display the drive operational status.Figure 28 Disk drive sta tus indicators1. Activity indi

Página 153 - Host conditions

Table 13 Operation al drive status displaysActivityOn-lineFaultDescriptionFlashing(medium speed)OnOffInitial startup.On OnOffThe operational drive is

Página 154

CXO6824B Figure 29 Drive blankReplacing adisk or drive blankTo replace a disk, comp lete the procedures outlined in Appendix D: Customer Replaceable U

Página 155 - GUI termination event display

3. AC Input connector with bail4. Module latch (port-wine colored)5. Blower tabs (port-wine colored)6. Blower elementEnclosure powerThe two power supp

Página 156 - Fault management displays

0.4.en.04CRITICALcondition—Lowtemperature... 1430.4.en.05UNRECOVERABLEcondition—Hightemperature ... 143EMUconditions...

Página 157

NOTE:The blower units are field- replaceable units. The units can be replaced, individually, while the system isrunning. The units are also interchange

Página 158 - Description

CXO7971A1Figure 32 EMU location1. EMUControls and displaysFigure 33 identifies the location and function of the EMU displays, controls, and connectors.

Página 159 - Common replacement procedures

WARNING!To reduce the risk of electrical shock, fire, or damage to the equipment, do not plug telephone ortelecommunications connectors into the “RS23

Página 160 - Replacing a disk drive

Table 16 EMU monitoring functionsElement Monitored FunctionsBlowers• Installation• Removal• Type• Speed (rpm)Disk drives• Installation• Removal• Bypas

Página 161

CXO6819A312Figure 34 EMU s tatus LEDs1. EMU Status LEDThis flashing green LED is the heartbeat for an operational EMU.2. Enclosure Power Status LEDThis

Página 162 - How to install a drive blank

Table 18 EMU LED displaysEMU LED green Power LEDgreenFault LED amber Status and recommended ac tionsFlashing Flashing FlashingThe EM U locate function

Página 163 - Howtoremoveadriveblank

2. Function select (top push-button)3. Display Group select (bottom push-button)NOTE:7-segmentdisplaylimitationsprecludedisplayinguppercasecharactersB

Página 164 - Customer replaceable units

NOTE:Any time you press and release the bottom push-button (see 3, Figure 35) , the display will change toEn, Li, rG, Au, or Er.A flashing alphanumeric

Página 165 - Glossary

• Correct all errors, thereby silencing the alarm until a new error o ccurs.• “Mute,” or temporarily disable, the alarm by pressing and holding the bo

Página 166

Disabling the audible alarmCAUTION:Disabling the audible alarm increases the potential of damage to equipment from a reported butunobserved fault. HP

Página 167

Replacingadiskdrive ... 160InsertingdiskdrivesintoarunningEVA... 161Howtoinstalladriveblank...

Página 168

Adisplayof00 indicates that the enclosure is not connected to the enclosure address bus. Whenthis condition exists, there is no EMU-to-EMU communicati

Página 169

CXO7956A5678910111213141423Figure 36 Enclosure n umbering with JBsEnterprise Virtual Array 3000/5000 user guide (VCS 3.110)81

Página 170

0046a-2131312345678910111213Figure 37 Enclosure numbe ring with shelf I D expansion c ablesNOTE:If an expansion rack is used with your Enterprise confi

Página 171

CXO7957B1158741231069Figure 38 Enclosure address bus components with JBsCallouts:Junction Boxes (JB)1. JB 1– Enclosures 1 and 22. JB 2–Enclosures 3 an

Página 172

Figure 39 Enclosure address b u s components with sh elf ID expansion ca blesCallouts:1. Shelf ID expansion cable port 1—Enclosure 12. Shelf ID expans

Página 173

• Information conditionSee Appendix B: EMU Generated Condition Reports for definitions of individual condition reports.When the audible alarm is not mu

Página 174

A CRITICAL condition has precedence over NON CRITICAL and INFORMATION conditions, but does nothave precedence over UN RECOVERABLE conditions.When this

Página 175

Condition report formatEach condition report identifies the element affected (type and number), and the primary problem (theerror code). Appendix B: EM

Página 176

Condition report analysisAs described in Appendix B: EMU Generated Condition Reports, condition report analysis involves:1. Identifying the element.2.

Página 177

Verifying enclosure operationCheck the enclosure status LEDs in the front, lower right corner (see Figure 40). If the display is notexactly as s hown,

Página 178

Figures1..Enterprise Virtual Array 2C12D configuration ... 172..EnterpriseVirtualArraystoragesolution... 203..Comman

Página 179

CXO7959AFigure 41 Locatio n of LED s tatus d is plays—enclosure rearTable 21 LED status displaysEMU LEDs and icons The enclosure power (both the +5 VD

Página 180

Table 22 Enclosure status icon displaysIconOffOnFlashingEMU “Heartbeat” Icon(green LED)Power Icon (green LED)Enclosure Status Icon(orange LED)Fibre Ch

Página 181

If the Port Bypass LEDs are blinking at a constant rate and the POST Fault LED is On, the switch detected afault during the POST. When a POST detects

Página 182

Table 24 Fibre Channel switch port LEDsSFP status LEDGreenPort bypassedLED amberDescriptionOff OffIndicates that the port does not have an SFP in stal

Página 183

CXO8040AFrontRear12910876 5 43 Figure 44 HSV110 controller—front and rear views1. Bezel2. OCP3. HF1 port4. HF2 port5. Mirror port6. 1B port7. 2B port8

Página 184

CXO7638A12 3Figure 45 Controller OCP1. Status LEDs (see LEDs)2. 40–character alphanumeric display (see LEDs)3. Push-buttons (see Displaying the Storag

Página 185

NOTE:An active (fl ashing) display, an error condition message, or a user entry (pressing a push-button)overrides the default display. When none of the

Página 186

Table 27 Menu options within the OCP displayMenu OptionsInformationFault Manag ement ShutdownOptionsSystem PasswordPort ConfigLast F aultRestartChange

Página 187

Displaying Versions system informationWhen you press , the active display is Versions. From the Versions display you can determine the:• VCS revision

Página 188

17 . Press to display the Bat tery PIC.18. Pressto display the Versions Menu tree.19 . Pressto scroll to the PowerPC Processor.20. Pressto display the