Standard required time*RAID levelRotation per minute
35 minutes6D+2PRAID 6
20 minutes14D+2P
110 minutes2D+2DRAID 110 Krpm
70 minutes3D+1PRAID 5
35 minutes7D+1P
35 minutes6D+2PRAID 6
20 minutes14D+2P
185 minutes2D+2DRAID 17.2Krpm
120 minutes3D+1PRAID 5
50 minutes7D+1P
65 minutes6D+2PRAID 6
25 minutes14D+2P
*Data drive capacity is assumed to be 1 TB.
For flash drives (SSDs):
Standard required time*RAID levelNumber of parity groups
30 minutes2D+2DRAID 1From 1 to 4
20 minutes3D+1PRAID 5
15 minutes7D+1P
15 minutes6D+2PRAID 6
10 minutes14D+2P
*Flash drive capacity is assumed to be 1 TB.
For FMDs:
Standard required time*RAID levelNumber of parity groups
20 minutes2D+2DRAID 1From 1 to 4
10 minutes3D+1PRAID 5
10 minutes7D+1P
10 minutes6D+2PRAID 6
5 minutes14D+2P
*FMD capacity is assumed to be 1 TB.
When host I/Os are performed, the required shredding time is at least six times that of when no
host I/Os are performed. If a DKxxx-HxxxAT data drive is used for creating a parity group on an
encrypted data drive, the time required for shredding that parity group is the maximum time listed.
If the volumes to be shredded belong to drives of mixed types or mixed configurations, the longest
required times associated with the drive type or drive configuration apply to all volumes. Thus,
mixed types and configurations take more time for the volumes to become available for use than
when the drive type and drive configuration are the same. When you add drives or change drive
6 Overview of Volume Shredder