27.9.3 Physical interconnect warnings and errors
Possible cause and recommendationSymptom
Interconnect warnings or errors due to:
Downlink with a deployed connection is not operational
Incorrect firmware version (different from firmware baseline version)
Configuration error
Hardware fault
Lost communication
Connection and redundancy status (no redundant paths)
Administratively disabled ports
Interconnect-level
warnings or errors
27.10 Troubleshooting networks
27.10.1 Network create operation is unsuccessful
Possible cause and recommendationSymptom
The prerequisites have not been met
1. Verify that the prerequisites listed in the online help have been met.
2. Retry the create network operation.
The network was configured incorrectly
1. Verify that:
The VLAN ID is in the range of valid integers (2 through 4092).
The network name is unique.
The network bandwidth is within the range indicated by the UI. The preferred bandwidth
must be less than the maximum bandwidth.
2. Retry the create network operation.
Network creation is
unsuccessful
27.11 Troubleshooting server hardware
27.11.1 Server add or remove is unsuccessful
If the add server action is not successful, a notification panel provides the reason why the add
action failed and provides a solution to the problem. Often, the resolution is to click the add link