Manual for: SU-2A Gas Burner
50,000 BTU/H to 250,000 BTU/H
The burner shall be used only with NATURAL GAS or LP GAS as specified on the nameplate.
Warning:
If the following instructions are not followed exactly, a fire or
explosion may result, causing property damage, personal injury or death.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity
of this or any other appliance.
-
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical appliance.
Do not use any phone in your building.
Immediately call your gas supplier from a neighbor’s phone.
Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire department.
A qualified installer, service agency or the gas supplier must perform installation and service.
All installations must be made in accordance with all state and local codes, which may differ
from instructions in this manual.
The installer should inform and demonstrate to the user the correct operation and maintenance
of the appliance.
The installer shall also inform the user of hazards of flammable liquids and vapors and shall
remove such liquids and vapors from the vicinity of the burner.
The installation adjustment data trap, or label supplied, shall be filled in and affixed to the
burner or the covered appliance.
These instructions should be affixed to the burner or adjacent to the heating appliance
NYC MEA # 382-03-E
Massachusetts Plumbing Board G1-0903-40:09/03/2004
Manufactured by Heat Wise, Inc.
1528 Rocky Point Road, Middle Island, NY 11953
rev 2004-2
Vista de página 0
1 2 3 4 5 6 ... 15 16

Resumo do Conteúdo

Página 1 - Manual for: SU-2A Gas Burner

1 Manual for: SU-2A Gas Burner 50,000 BTU/H to 250,000 BTU/H The burner shall be used only with NATURAL GAS or LP GAS as specified on the nameplate

Página 2 - BURNER DESCRIPTION

10 Fig. 5 Wiring Diagram for Honeywell S89F SEQUENCE OF OPERATIONS Honeywell S89F 1. Limits close. 2. Blower motor starts as the 24 Volt trans

Página 3 - AIR FOR COMBUSTION

11 LIGHTING INSTRUCTIONS To light the SU-2A Gas Burner 1. Set the thermostat to the lowest temperature 2. The control knob on the gas valve should

Página 4 - CHIMNEY REQUIREMENTS

12 PICTURE 4: HEAD AND AIR ADJUSTMENT Head Air When to adjust the Air The air shutter is a mechanical shutter. Do

Página 5 - Chart 3: Vent Pipe Sizing

13 Trouble shooting: There are three factors to operate the gas burner properly: 1. Electricity {(main Power 120V/60 Hz /1 Ph)( secondary 24V)} 2.

Página 6 - Pipe Length**

14 ITEM PART PART # ITEM PART PART # 1 Blast Tube 11728410 16 Cover Plate - Air Regulation 11887001 2 Flange Gasket 10195-1 16A Cover

Página 7 - CONFORM TO LOCAL CODES

15 Maintenance Instructions: TO BE FIXED/ATTACHED NEAR BURNER Once a year, a qualified service agency needs to be contracted for other than routine

Página 9 - ELECTRIC WIRING

2 Chart 1: Natural Gas and LP Firing Rate Burner Model Length of Flame Tube Min BTU/H Max BTU/H Primary Electric Input Secondary Electric Input To

Página 10 - SEQUENCE OF OPERATIONS

3CONVERTING OIL TO GAS Before attempting the gas conversion, check to insure the heating system is properly sized for the total heating demand an

Página 11 - BURNER OPERATION

4CHIMNEY REQUIREMENTS The chimney should extend at least 3’ above a flat roof or the highest roof ridge (see Fig. 2) and be free in a radius of 30’

Página 12

5 VENT PIPE AND DRAFT HOOD SIZES Refer to Chart 3 to properly size the flue pipe. If the flue pipe exceeds 10’ in length (including elbows), use t

Página 13 - Condition Solutions

6 GAS SERVICE & PIPE CAPACITY Before connecting the burner to the gas supply, insure that the gas pipes and service meter are large e

Página 14

7It is advisable to run a separate gas line from the meter to the gas burner to avoid pressure drops. Refer to the above Pipe Capacity table for th

Página 15 - Maintenance Instructions:

8 ORIFICE INSTALLATION All burners are equipped with an orifice set at the minimum firing rate (except for OEM packaged units). Drilling the ori

Página 16

9ELECTRIC WIRING These gas burners are manufactured for use with 120 volt, 60 cycle, single-phase electric current. The installation must comply