Hp HSG Array Controller Manual do Utilizador Página 148

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 248
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 147
B-8 StorageWorks Fibre Channel Storage Switch User's Guide
Compaq Confidential – Need to Know Required
Writer: Bill Reitz Project: StorageWorks Fibre Channel Storage Switch User's Guide Comments:
Part Number: AA-RHBYA-TE 135267-001 File Name: i-appb Telnet Commands Last Saved On: 4/7/99 12:36 PM
Date and time of the first occurrence each error type was sensed
Total number of occurrences of each error type (up to 999)
The maximum error number is 999.
Error type
Error level for each error type
0–Panic (when this level is reached, the Switch automatically
reboots and the display no longer shows the error)
1–Critical
2–Error
3–Warning
4–Debug
The following information is displayed in Figure B-6:
The Switch detected two errors.
The task ID and task name that incurred the error (task names are
displayed using the i command). For example, 0x103dc470.
The error type, date and time, the error level, and description.
If there is more than one occurrence of an error type, the number of
occurrences is shown in brackets following the error date and time.