A Specifications
Hardware Specifications
Primary Power
Voltage Limits
The tape drives are capable of using any nominal AC voltage between 100 and 240 V
ac power, at 50 or 60 Hz. The machines are capable of powering up and operating
without error from any voltage within the ranges specified:
Frequency Limits
The tape drive are capable of operation at either 50 Hz or 60 Hz. They automatically
adjust for 50-60 Hz primary power operation, without requiring user intervention or
modification.
Table A-1. Hardware Specifications
Operation Specification
SCSI Interface HVD
Drive Configuration 1
Number of Cartridges 15
Maximum Data Capacity 6.0 terabytes
Maximum Transfer Rate 115.2 gigabytes/hour
Mount Time, into Tape Drive 10 seconds
Dismount Time, from Tape Drive 10 seconds
Reliability
MTBF 250,000 hours
MSBF 2,000,000 cartridge cycles
Design Life 7 yrs. @ 30 % duty cycle
MTTR 10 minutes
Physical Characteristics (Tabletop)
Height 9.1 inches
Width 19 inches
Depth 31.5 inches
Weight 58 pounds