Hp ProLiant DL360e Gen8 Server Manual do Utilizador Página 12

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 11
Component identification 12
administrators is to restart the system. Resetting the system erases any information which could support
problem analysis, but the NMI feature preserves that information by performing a memory dump before a
system reset.
To force the system to invoke the NMI handler and generate a crash dump log, do one of the following:
Use the iLO Virtual NMI feature.
Short the NMI header ("System board components" on page 9).
For more information, see the HP website (http://www.hp.com/support/NMI).
Drive numbering
Four-bay LFF drive model
Eight-bay SFF drive model
When the two-port SATA cable is installed in the eight-bay drive cage ("Two-port SATA cable option"
on page 32), the server supports the six-drive SATA configuration. In this configuration, drive bays 1
through 6 are populated, while drive bays 7 and 8 contain drive blanks.
Drive LED definitions
Item LED Status Definition
1
Locate Solid blue The drive is being identified by a host application.
Flashing blue The drive carrier firmware is being updated or requires an update.
2
Activity ring Rotating green Drive activity
Off No drive activity
3
Do not remove Solid white Do not remove the drive. Removing the drive causes one or more of
the logical drives to fail.
Off Removing the drive does not cause a logical drive to fail.
4
Drive status Solid green The drive is a member of one or more logical drives.
Vista de página 11
1 2 ... 7 8 9 10 11 12 13 14 15 16 17 ... 113 114

Comentários a estes Manuais

Sem comentários