HP ProLiant XL220a Gen8 v2 Server
User Guide
Abstract
This document is for the person who installs, administers, and troubleshoots servers and storage systems. HP assumes you are qualified in the
servicing of computer equipment and trained in recognizing hazards in products with hazardous energy levels.
Part Number: 752048-001
June 2014
Edition: 1
Vista de página 0
1 2 3 4 5 6 ... 73 74

Resumo do Conteúdo

Página 1 - User Guide

HP ProLiant XL220a Gen8 v2 Server User Guide Abstract This document is for the person who installs, administers, and troubleshoots servers and stora

Página 2

Component identification 10 Drive numbering Item Description 1 Drive bay 2 (node 1) 2 Drive bay 1 (node 1) 3 Drive bay 1 (node 2) 4 Drive bay 2

Página 3 - Contents

Component identification 11 Item LED Status Definition 1 Locate Solid blue The drive is being identified by a host application. Flashin

Página 4 - Contents 4

Operations 12 Operations Power down the server Before powering down the server for any upgrade or maintenance procedures, perform a backup of critic

Página 5 - Contents 5

Operations 13 Remove the drive 1. Determine the status of the drive from the drive LED definitions ("Hot-plug drive LED definitions" on p

Página 6 - Component identification

Operations 14 Remove the processor air baffle 1. Power down the server (on page 12). 2. Disconnect all peripheral cables from the server. 3. Remo

Página 7 - Front panel LEDs and buttons

Operations 15 6. Remove the PCI riser board assembly. A T-10 screwdriver (for horizontal screws) and a T-15 screwdriver (for vertical screws) are re

Página 8 - System board components

Operations 16 8. Disconnect the front panel LED board assembly cables. 9. Remove all drives ("Remove the drive" on page 13). 10. Remove

Página 9 - System maintenance switch

Operations 17 Install the processor air baffle 1. Install the processor air baffle. IMPORTANT: If the DIMM latches are not fully closed, the b

Página 10 - Drive numbering

Operations 18 2. Install the PCI riser board assembly. 3. Connect all cables to existing expansion boards. 4. Install the server (on page 18). 5

Página 11

Operations 19 To install the component: 1. Prepare the server for installation. 2. Install the server. When seated properly, the server will be f

Página 12 - Operations

© Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties

Página 13 - Remove the server

Setup 20 Setup Setup overview Installation of a server requires the following steps: 1. Install and configure a chassis. 2. Install any server opt

Página 14

Setup 21 CAUTION: To prevent improper cooling and thermal damage, do not operate the chassis unless all bays are populated with a component or a b

Página 15

Setup 22 Installing the operating system To operate properly, the server must have a supported operating system installed. For the latest informatio

Página 16 - Operations 16

Hardware options installation 23 Hardware options installation Introduction If more than one option is being installed, read the installation instru

Página 17

Hardware options installation 24 c. Remove the heatsink from the processor backplate. WARNING: To reduce the risk of personal injury from hot s

Página 18 - Install the server

Hardware options installation 25 CAUTION: THE PINS ON THE SYSTEM BOARD ARE VERY FRAGILE AND EASILY DAMAGED. To avoid damage to the system board: •

Página 19 - Operations 19

Hardware options installation 26 4. Apply all the grease to the top of the processor in the following pattern to ensure even distribution. 5. Inst

Página 20

Hardware options installation 27 Memory subsystem architecture The memory subsystem in this server is divided into channels. The processor supports

Página 21 - Powering up the chassis

Hardware options installation 28 Item Description Definition 1 Size — 2 Rank 1R = Single-rank 2R = Dual-rank 3R = Three-rank 4R = Quad-rank

Página 22 - Registering the server

Hardware options installation 29 CAUTION: To avoid damage to the drives, memory, and other system components, the air baffle, and drive blanks mus

Página 23 - Processor option

Contents 3 Contents Component identification ...

Página 24

Hardware options installation 30 Drive guidelines When adding drives to the server, observe the following general guidelines: • The system automat

Página 25

Hardware options installation 31 Controller options The server supports installation of controller options in the PCI riser assembly for node 1 and

Página 26 - Memory options

Hardware options installation 32 FBWC cache module and capacitor pack option To install the component: 1. Power down the server (on page 12). 2. D

Página 27 - DIMM identification

Hardware options installation 33 9. Install the FBWC capacitor pack into the holder mounted in the server. 10. Route the capacitor pack cables as

Página 28 - Installing a DIMM

Hardware options installation 34 o Node 2 11. Connect and route all drive cables. For more information, see "Drive cabling (on page 52)."

Página 29

Hardware options installation 35 • When installing or replacing hardware, HP service providers cannot enable the TPM or the encryption technology.

Página 30 - Installing a hot-plug drive

Hardware options installation 36 8. Install the TPM security rivet by pressing the rivet firmly into the system board. 9. Install the PCI riser bo

Página 31 - Controller options

Hardware options installation 37 8. Enable the TPM in the OS. For OS-specific instructions, see the OS documentation. CAUTION: When a TPM is ins

Página 32

Software and configuration utilities 38 Software and configuration utilities Server mode The software and configuration utilities presented in this

Página 33

Software and configuration utilities 39 iLO 4 enables and manages the Active Health System (on page 39) and also features Agentless Management. All

Página 34

Contents 4 HP Trusted Platform Module option ...

Página 35

Software and configuration utilities 40 The data that is collected is managed according to the HP Data Privacy policy. For more information see the

Página 36

Software and configuration utilities 41 HP Insight Diagnostics Offline Edition performs various in-depth system and component testing while the OS i

Página 37

Software and configuration utilities 42 HP Insight Remote Support is available as part of HP Warranty, HP Care Pack Service, or HP contractual suppo

Página 38 - HP iLO Management

Software and configuration utilities 43 ProLiant BL, ML, DL, and SL servers. The toolkit includes a modular set of utilities and important documenta

Página 39 - Active Health System

Software and configuration utilities 44 • Language selection For more information on RBSU, see the HP ROM-Based Setup Utility User Guide on the HP

Página 40 - Intelligent Provisioning

Software and configuration utilities 45 Boot options Near the end of the boot process, the boot options screen is displayed. This screen is visible

Página 41 - Erase Utility

Software and configuration utilities 46 Utilities and features Array Configuration Utility ACU is a utility with the following features: • Runs as

Página 42 - HP Insight Online

Software and configuration utilities 47 HP Smart Storage Administrator HP SSA is a configuration and management tool for HP Smart Array controllers.

Página 43 - HP ROM-Based Setup Utility

Software and configuration utilities 48 For more information, go to the HP website (http://www.hp.com/go/hpsc) and click on Drivers, Software &

Página 44 - Auto-configuration process

Software and configuration utilities 49 Keeping the system current Drivers IMPORTANT: Always perform a backup before installing or updating devi

Página 45 - Configuring AMP modes

Contents 5 Electrostatic discharge ...

Página 46 - Utilities and features

Software and configuration utilities 50 HP operating systems and virtualization software support for ProLiant servers For information about specific

Página 47 - ROMPaq utility

Troubleshooting 51 Troubleshooting Troubleshooting resources The HP ProLiant Gen8 Troubleshooting Guide, Volume I: Troubleshooting provides procedur

Página 48 - Redundant ROM support

Cabling 52 Cabling Internal server cabling This section provides guidelines that help you make informed decisions about cabling the server and hardw

Página 49 - Keeping the system current

Cabling 53 Front panel LED board assembly cabling FBWC capacitor pack cabling SUV cable connectors CAUTION: Before disconnecting the SUV cab

Página 50 - ProLiant servers

Cabling 54 Item Connector Description 1 Serial For trained personnel to connect a null modem serial cable and perform advanced diagnostic p

Página 51 - Troubleshooting

Regulatory information 55 Regulatory information Safety and regulatory compliance For safety, environmental, and regulatory information, see Safety

Página 52 - Cabling

Regulatory information 56 Valid date formats include the following: • YWW, where Y indicates the year counting from within each new decade, with 20

Página 53 - SUV cable connectors

Electrostatic discharge 57 Electrostatic discharge Preventing electrostatic discharge To prevent damaging the system, be aware of the precautions yo

Página 54 - Item Connector Description

Specifications 58 Specifications Environmental specifications Specification Value Temperature range* — Operating 10°C to 35°C (50°F to 95°F) Shi

Página 55 - Regulatory information

Support and other resources 59 Support and other resources Before you contact HP Be sure to have the following information available before you call

Página 56 - Warranty information

Component identification 6 Component identification Front panel components Item Description 1 Drive bay 2 (node 1) 2 Drive bay 1 (node 1) 3 SUV c

Página 57 - Electrostatic discharge

Support and other resources 60 providers or service partners) identifies that the repair can be accomplished by the use of a CSR part, HP will ship

Página 58 - Specifications

Support and other resources 61 Pour plus d'informations sur le programme CSR de HP, contactez votre Mainteneur Agrée local. Pour plus d'in

Página 59 - Support and other resources

Support and other resources 62 HINWEIS: Einige Teile sind nicht für Customer Self Repair ausgelegt. Um den Garantieanspruch des Kunden zu erfüllen,

Página 60

Support and other resources 63 sustituciones que lleve a cabo el cliente, HP se hará cargo de todos los gastos de envío y devolución de componentes

Página 61 - Customer Self Repair

Support and other resources 64 Opcional – Peças cujo reparo feito pelo cliente é opcional. Essas peças também são projetadas para o reparo feito pel

Página 62

Support and other resources 65

Página 63 - Reparo feito pelo cliente

Support and other resources 66

Página 64

Acronyms and abbreviations 67 Acronyms and abbreviations ABEND abnormal end ACU Array Configuration Utility ADM Advanced Data Mirroring AMP Advan

Página 65

Acronyms and abbreviations 68 HP SIM HP Systems Insight Manager HP SSA HP Smart Storage Administrator HP SUM HP Smart Update Manager iLO Integrat

Página 66

Acronyms and abbreviations 69 RBSU ROM-Based Setup Utility RDIMM registered dual in-line memory module RDP Rapid Deployment Pack RoHS Restriction

Página 67 - Acronyms and abbreviations

Component identification 7 Front panel LEDs and buttons Item Description Status 1 NIC 1 LED (node 1) Solid green = Link to network Flashing gr

Página 68

Acronyms and abbreviations 70 UDIMM unregistered dual in-line memory module UID unit identification VCA Version Control Agent VCRM Version Contro

Página 69

Documentation feedback 71 Documentation feedback HP is committed to providing documentation that meets your needs. To help us improve the documentat

Página 70 - Version Control Agent

Index 72 A ACU (Array Configuration Utility) 38, 46, 47 air baffle, installation 17 air baffle, removal 14 Array Configuration Utility (ACU)

Página 71 - Documentation feedback

Index 73 installing I/O modules 20 installing operating system 22 installing the processor air baffle 17 Integrated Lights-Out (iLO) 38, 40

Página 72 - Index 72

Index 74 W website, HP 59

Página 73 - Index 73

Component identification 8 Item Description Status 6 Power On/Standby button and system power LED (node 2) Solid green = System on Flashing green

Página 74 - Index 74

Component identification 9 Item Description 16 PCIe riser board connector (node 2) 17 System maintenance switch (node 2) 18 Drive backplane power c

Modelos relacionados Apollo 6000 Chassis

Comentários a estes Manuais

Sem comentários