HP 100Base-T Hubs Installation and Reference Guide
A-2 Troubleshooting
functioning properly. If any component fails the diagnostic
test, contact your HP-authorized reseller for assistance.
System Diagnostics
Power and Cooling Problems
If the 3RZHU indicator does not turn on when the power cord is
plugged in, you may have a problem with the power outlet,
power cord, or internal power supply as explained in the
previous section. However, if the unit powers off after running
for a while, check for loose power connections, power losses or
surges at the power outlet, and verify that the fans on the back
of the unit are unobstructed and running prior to shutdown. If
you still cannot isolate the problem, then the internal power
supply may be defective. In this case, contact
your
HP-authorized reseller for assistance.
Installation
Verify that all system components have been properly installed.
If one or more components appear to be malfunctioning (e.g.,
the power cord or network cabling), test them in an alternate
environment where you are sure that all the other components
are functioning properly.
Transmission Mode
If any devices are attached to a 10/100TX Switch Port Module,
and operate at full duplex but do not support auto-negotiation,
then you must manually set the transmission mode for this port
on the hub. The transmission mode must always be set
manually for the 100FX Switch Port Module.
The default method of selecting the transmission mode for the
10/100TX Switch Port Module is auto-negotiation. Therefore, if
the
/LQN signal is disrupted (e.g., by unplugging the network cable