STatus <port group>
To display status information for the hub, including the time elapsed since the
last reset (see the Reset command), the hub’s station address, the Thinwatch
setting, and a table with the following port information:
For the Hub/12 and Hub Plus, do not specify a port group.
For the Hub Plus/48, the <port group> parameter is a letter A, B, C, or D. If no port group
is specified, all ports will be displayed.
Port
The port ID. (For the HP 28688B and HP 28699A, BKUP indicates
the port is configured as the backup link, PRI indicates the port is
the primary link).
Port Status The status of each port:
ON means the port is enabled and is not auto-segmented.
OFF means the port has been explicitly disabled.
SEGMENTED means the port has been auto-segmented.
(See “Auto-Segmentation” in chapter 1.)
ON/REVERSED means that reversed wiring polarity on the receive
pair has been detected on a twisted-pair cable and the hub has
compensated.
Link Beat The link beat status of each twisted-pair port:
OFF means link beat has been explicitly disabled.
NOT DETECTED means link beat is enabled but is not detected.
(Note: If a packet is received on a port with a missing link beat,
the port will be enabled for a short time. This may cause its port
LED to flash intermittently.) This field is blank if the port is
disabled.
Station Address The station address of the device connected to each port, or:
NONE meaning an address has not yet been detected. A device
must transmit packets to be detected.
MULTIPLE meaning more than one address has been detected.
Operation 3-9