Maintenance
Processor Diagnostics - MVME197
197-Diag> sd
197-Bug> bo 0 0
VMEDKHS Diagnostics
After configuring the CPM-HS module, if a connection problem is encountered,
the screen below will be displayed.
NOTICE: DKHS0:Interface is down: TX-HANG
. . .
**********
** The CommKit Server for morse is having problems
** Please get someone to attend to it.
** The last error was:May 16 07:49:20(273)[0]dkmgr:Can’t open /dev/dk/dial0
**********
If you receive these error messages:
1 . Check the cabling:
The newer CPM-HS modules have a red LED on the paddleboard
which indicates if the cable has not been installed correctly. If this
LED is lit, check the cable connection. If the connection is complete,
reverse the fiber cable connection on either the LCS60 or the CPM-
HS (whichever is more convenient).
If the error message is still displayed, check the VMEDKHS board
in the LCS60.
Issue 3 9-25