HP Insight Integration Module for IBM Netcool/OMNIbus User Guide, Revision 5.0 Part number 670651-001 First edition 08/2011

Página 2 - Intended audience

Product overview 10 • Microsoft Windows 2000 Advanced Server • Microsoft Windows 2003 Server • Microsoft Windows 2000 Professional—Desktop c

Página 3 - Contents

Appendix B: HP SNMP events 100 Trap types Rules file Description Netcool severity sCellEventTrap-0c-6b(13603179) 13603179 This event occurs w

Página 4 - Contents 4

Appendix B: HP SNMP events 101 Trap types Rules file Description Netcool severity 34(13603380) missing. This might affect the drive enclosur

Página 5 - Contents 5

Appendix B: HP SNMP events 102 Trap types Rules file Description Netcool severity f0(13603568) on one or more of the drive enclosures. This

Página 6 - About this guide

Appendix B: HP SNMP events 103 Trap types Rules file Description Netcool severity sCellEventTrap-0e-1e(13603614) 13603614 This event occurs w

Página 7 - Product overview

Appendix B: HP SNMP events 104 Trap types Rules file Description Netcool severity 3a(13603642) module is operating normally. sCellEventTrap-

Página 8 - HP software requirements

Appendix B: HP SNMP events 105 Trap types Rules file Description Netcool severity controller. sCellEventTrap-11-01(13604353) 13604353 This ev

Página 9 - ○ UnitedLinux 1.0

Appendix B: HP SNMP events 106 Trap types Rules file Description Netcool severity sCellEventTrap-85-07(13634055) 13634055 This event occurs w

Página 10 - Product overview 10

Appendix B: HP SNMP events 107 Trap types Rules file Description Netcool severity mngmtAgentTrap-17(136000017) 136000017 This event occurs wi

Página 11 - Installation notes

Appendix B: HP SNMP events 108 Trap types Rules file Description Netcool severity mngmtAgentTrap-39(136000039) 136000039 This event occurs wi

Página 12 - Merging the rules

Appendix B: HP SNMP events 109 Trap types Rules file Description Netcool severity mngmtAgentTrap-60(136000060) 136000060 This event occurs wi

Página 13

Installation notes 11 Installation notes Netcool/OMNIbus components Operation of the Netcool/OMNIbus relies on the following three major compone

Página 14 - Network Adapter Status

Appendix B: HP SNMP events 110 Trap types Rules file Description Netcool severity allowed. mngmtAgentTrap-80(136000080) 136000080 This event

Página 15

Appendix B: HP SNMP events 111 Trap types Rules file Description Netcool severity 99(136000099) destination connection is down. mngmtAgentTr

Página 16 - Event correlation

Appendix B: HP SNMP events 112 Trap types Rules file Description Netcool severity mngmtAgentTrap-120(136000120) 136000120 This event occurs w

Página 17 - Customizing the rules file

Appendix B: HP SNMP events 113 Trap types Rules file Description Netcool severity mngmtAgentTrap-182(136000182) 136000182 This event occurs w

Página 18 - Technical support

Appendix B: HP SNMP events 114 Trap types Rules file Description Netcool severity 211(136000211) Restore Mode incompatible. mngmtAgentTrap-2

Página 19 - Troubleshooting

Appendix B: HP SNMP events 115 Trap types Rules file Description Netcool severity mngmtAgentTrap-1011(136001011) 136001011 This event occurs

Página 20 - Appendix B: HP SNMP events

Appendix B: HP SNMP events 116 Trap types Rules file Description Netcool severity mngmtAgentTrap-2026(136002026) 136002026 This event occurs

Página 21

Appendix B: HP SNMP events 117 Trap types Rules file Description Netcool severity mngmtAgentTrap-2061(136002061) 136002061 This event occurs

Página 22

Appendix B: HP SNMP events 118 Trap types Rules file Description Netcool severity 2076(136002076) healthy disk group(s) to create a Vdisk. R

Página 23

Appendix B: HP SNMP events 119 Trap types Rules file Description Netcool severity mngmtAgentTrap-2095(136002095) 136002095 This event occurs

Página 24

Installation notes 12 Merging the rules To merge the new rules files into the IBM Tivoli Netcool/OMNIbus Netcool Knowledge Library: NOTE: The

Página 25

Appendix B: HP SNMP events 120 Trap types Rules file Description Netcool severity mngmtAgentTrap-3004(136003004) 136003004 This event occurs

Página 26

Appendix B: HP SNMP events 121 Trap types Rules file Description Netcool severity mngmtAgentTrap-3044(136003044) 136003044 This event occurs

Página 27

Appendix B: HP SNMP events 122 Trap types Rules file Description Netcool severity mngmtAgentTrap-3063(136003063) 136003063 This event occurs

Página 28

Appendix B: HP SNMP events 123 Trap types Rules file Description Netcool severity mngmtAgentTrap-3083(136003083) 136003083 This event occurs

Página 29

Appendix B: HP SNMP events 124 Trap types Rules file Description Netcool severity 4017(136004017) to find storage system object. mngmtAgentT

Página 30

Appendix B: HP SNMP events 125 Trap types Rules file Description Netcool severity 4047(136004047) Previously Read Object Properties do not M

Página 31

Appendix B: HP SNMP events 126 Trap types Rules file Description Netcool severity 5007(136005007) create timer error. mngmtAgentTrap-5008(13

Página 32

Appendix B: HP SNMP events 127 Trap types Rules file Description Netcool severity mngmtAgentTrap-6006(136006006) 136006006 This event occurs

Página 33

Appendix B: HP SNMP events 128 Trap types Rules file Description Netcool severity Enclosure Power Off Requested. mngmtAgentTrap-6027(13600602

Página 34

Appendix B: HP SNMP events 129 Trap types Rules file Description Netcool severity mngmtAgentTrap-8007(136008007) 136008007 This event occurs

Página 35

Using the HP Insight Integration module for Netcool/OMNIbus 13 Using the HP Insight Integration module for Netcool/OMNIbus Introduction The inte

Página 36

Appendix B: HP SNMP events 130 Trap types Rules file Description Netcool severity mngmtAgentTrap-8029(136008029) 136008029 This event occurs

Página 37

Appendix B: HP SNMP events 131 Trap types Rules file Description Netcool severity mngmtAgentTrap-8051(136008051) 136008051 This event occurs

Página 38

Appendix B: HP SNMP events 132 Trap types Rules file Description Netcool severity 8074(136008074) Derived Unit Count Failed. mngmtAgentTrap-

Página 39

Appendix B: HP SNMP events 133 Trap types Rules file Description Netcool severity mngmtAgentTrap-8096(136008096) 136008096 This event occurs

Página 40

Appendix B: HP SNMP events 134 Trap types Rules file Description Netcool severity 9016(136009016) data lost error resolved. mngmtAgentTrap-9

Página 41

Appendix B: HP SNMP events 135 Trap types Rules file Description Netcool severity 9034(136009034) allocation policy cannot be satisfied and

Página 42

Appendix B: HP SNMP events 136 Trap types Rules file Description Netcool severity 10014(136010014) Command rejected - Vdisk(s) are presented

Página 43

Appendix B: HP SNMP events 137 Trap types Rules file Description Netcool severity mngmtAgentTrap-10035(136010035) 136010035 This event occurs

Página 44

Appendix B: HP SNMP events 138 Trap types Rules file Description Netcool severity storage cell. mngmtAgentTrap-10053(136010053) 136010053 Thi

Página 45

Appendix B: HP SNMP events 139 Trap types Rules file Description Netcool severity it exceeds the maximum mirror item-count. mngmtAgentTrap-10

Página 46

Using the HP Insight Integration module for Netcool/OMNIbus 14 The following example shows the Event List. The Event List displays the event t

Página 47

Appendix B: HP SNMP events 140 Trap types Rules file Description Netcool severity mngmtAgentTrap-12005(136012005) 136012005 This event occurs

Página 48

Appendix B: HP SNMP events 141 Trap types Rules file Description Netcool severity mngmtAgentTrap-14010(136014010) 136014010 This event occurs

Página 49

Appendix B: HP SNMP events 142 Trap types Rules file Description Netcool severity mngmtAgentTrap-16014(136016014) 136016014 This event occurs

Página 50

Appendix B: HP SNMP events 143 Trap types Rules file Description Netcool severity Enclosure WWN. mngmtAgentTrap-16033(136016033) 136016033 Th

Página 51

Appendix B: HP SNMP events 144 Trap types Rules file Description Netcool severity failed. mngmtAgentTrap-17009(136017009) 136017009 This even

Página 52

Appendix B: HP SNMP events 145 Trap types Rules file Description Netcool severity mngmtAgentTrap-18001(136018001) 136018001 This event occurs

Página 53

Appendix B: HP SNMP events 146 Trap types Rules file Description Netcool severity 18042(136018042) Control Memory Allocation Failure. mngmtA

Página 54

Appendix B: HP SNMP events 147 Trap types Rules file Description Netcool severity mngmtAgentTrap-18076(136018076) 136018076 This event occurs

Página 55

Appendix B: HP SNMP events 148 Trap types Rules file Description Netcool severity 20022(136020022) string is null or in an incorrect format.

Página 56

Appendix B: HP SNMP events 149 Trap types Rules file Description Netcool severity mngmtAgentTrap-20045(136020045) 136020045 This event occurs

Página 57

Using the HP Insight Integration module for Netcool/OMNIbus 15 To obtain additional information, click the highlighted event to display the Eve

Página 58

Appendix B: HP SNMP events 150 Trap types Rules file Description Netcool severity mngmtAgentTrap-21017(136021017) 136021017 This event occurs

Página 59

Appendix B: HP SNMP events 151 Trap types Rules file Description Netcool severity 25010(136025010) Shutdown Drive Shelf Power Off But No Enc

Página 60

Appendix B: HP SNMP events 152 Trap types Rules file Description Netcool severity name exists on the remote storage system. mngmtAgentTrap-26

Página 61

Appendix B: HP SNMP events 153 Trap types Rules file Description Netcool severity command is issued through the XML interface. mngmtAgentTrap

Página 62

Appendix B: HP SNMP events 154 Trap types Rules file Description Netcool severity mngmtAgentTrap-27018(136027018) 136027018 This event occurs

Página 63

Appendix B: HP SNMP events 155 Trap types Rules file Description Netcool severity 27030(136027030) properties of a host, command is issued t

Página 64

Appendix B: HP SNMP events 156 Trap types Rules file Description Netcool severity issued through the XML interface. mngmtAgentTrap-27042(1360

Página 65

Appendix B: HP SNMP events 157 Trap types Rules file Description Netcool severity 29002(136029002) code load process is completed. mngmtAgen

Página 66

Appendix B: HP SNMP events 158 Trap types Rules file Description Netcool severity mngmtAgentTrap-(136000000) 136000000 This event occurs with

Página 67

Appendix B: HP SNMP events 159 Trap types Rules file Description Netcool severity fanFailureTrap (5) 5 This event occurs when the fan in the

Página 68

Using the HP Insight Integration module for Netcool/OMNIbus 16 Event correlation The rules and lookup files for Netcool/OMNIbus provides rules t

Página 69

Appendix B: HP SNMP events 160 Trap types Rules file Description Netcool severity externalInputInformationTrap (21) 21 This event occurs when

Página 70

Appendix B: HP SNMP events 161 Trap types Rules file Description Netcool severity cpqSwccEmuDevState:ok cpqSwccEmuDevState .2 — Clear (0) cp

Página 71

Appendix B: HP SNMP events 162 Trap types Rules file Description Netcool severity bt2SwDefGwNotInService(5) 5 This event occurs when the def

Página 72

Appendix B: HP SNMP events 163 Trap types Rules file Description Netcool severity bt2SwStgNewRoot(42) 42 This event occurs when the bridge b

Página 73

Appendix B: HP SNMP events 164 Trap types Rules file Description Netcool severity InternalMsgStatus:tooHigh InternalMsgStatus.8 — Major (4)

Página 74

Appendix B: HP SNMP events 165 Trap types Rules file Description Netcool severity alarmWaterCoolUnit (6) — This event occurs when status of W

Página 75

Appendix B: HP SNMP events 166 Trap types Rules file Description Netcool severity bntSwFwDownloadFailure (30) 30 This event occurs when the

Página 76

Appendix B: HP SNMP events 167 Trap types Rules file Description Netcool severity bntSwTempExceedThreshold (22) 22 This event occurs when the

Página 77

Appendix B: HP SNMP events 168 Trap types Rules file Description Netcool severity bntSwDefGwInService (4) 4 This event occurs when the defaul

Página 78

Appendix B: HP SNMP events 169 MSA2000 - TRAPS (MSA2000TRAPS.MIB) Trap types Rules file Description Netcool severity msaEventInfoTrap (3001)

Página 79

Using the HP Insight Integration module for Netcool/OMNIbus 17 Customizing the rules file If you must customize the rules file for the end use

Página 80

Appendix B: HP SNMP events 170 Trap types Rules file Description Netcool severity hpHttpMgDeviceRemovedTrap (9) 9 This event occurs when is re

Página 81

Appendix B: HP SNMP events 171 Trap types Rules file Description Netcool severity vcModPortOutputUtilizationUp(13) 13 This event occurs when t

Página 82

Appendix B: HP SNMP events 172 Trap types Rules file Description Netcool severity Severity: info severity.2 Clear(0) lhnNsmNotificationRAI

Página 83

Appendix B: HP SNMP events 173 Trap types Rules file Description Netcool severity lhnNsmNotificationMemory(12) — This event occurs when an ev

Página 84

Appendix B: HP SNMP events 174 Trap types Rules file Description Netcool severity lhnNsmNotificationVolume(20) — This event occurs when an ev

Página 85

Appendix C: Non-HP SNMP events 175 Appendix C: Non-HP SNMP events Non-HP SNMP events The following table lists all of the non-HP SNMP definition

Página 86

Appendix C: Non-HP SNMP events 176 Trap types Rules file Description Netcool severity connUnitPortStatus:Warning connUnitPortStatus .4 — Mino

Página 87

Appendix D: Insight SNMP rules 177 Appendix D: Insight SNMP rules Insight SNMP rules The following tables list all of the HP rules delivered wit

Página 88

Appendix D: Insight SNMP rules 178 Trap name OID () Caused by Cleared by New in revision 5.0 CpqCrEMUTemperatureCriticalTrap 24 — 25 — Cpq

Página 89

Appendix D: Insight SNMP rules 179 Trap name OID () Caused by Cleared by New in revision 5.0 CpqSeCpuStatus:Disabled CpqSeCpuStatus.5 — CpqSe

Página 90

Technical support 18 Technical support Before you contact HP Be sure to have the following information available before you call HP: • Technica

Página 91

Appendix D: Insight SNMP rules 180 Trap name OID () Caused by Cleared by New in revision 5.0 cpqSiHotPlugSlotErrorStatus: wrongSpeed cpqSiHot

Página 92

Appendix D: Insight SNMP rules 181 Trap name OID () Caused by Cleared by New in revision 5.0 CpqDaSpareStatus:inactive CpqDaSpareStatus .4

Página 93

Appendix D: Insight SNMP rules 182 Trap name OID () Caused by Cleared by New in revision 5.0 CpqDaTapeLibraryStatus:ok CpqDaTapeLibraryStat

Página 94

Appendix D: Insight SNMP rules 183 Trap name OID () Caused by Cleared by New in revision 5.0 CpqDaLogDrvStatus:shutdown CpqDaLogDrvStatus.1

Página 95

Appendix D: Insight SNMP rules 184 Trap name OID () Caused by Cleared by New in revision 5.0 CpqDaTapeLibraryStatus:offline CpqDaTapeLibrar

Página 96

Appendix D: Insight SNMP rules 185 Trap name OID () Caused by Cleared by New in revision 5.0 cpqDaCntlrPartnerBoardStatus:generalFailure cpq

Página 97

Appendix D: Insight SNMP rules 186 Trap name OID () Caused by Cleared by New in revision 5.0 CpqTapePhyDrvStatus:missingWasOk CpqTapePhyDrvS

Página 98

Appendix D: Insight SNMP rules 187 Trap name OID () Caused by Cleared by New in revision 5.0 cpqScsiLogDrvStatus: disabled cpqScsiLogDrvSta

Página 99

Appendix D: Insight SNMP rules 188 Trap name OID () Caused by Cleared by New in revision 5.0 cpqHeCorrMemLogStatus:enabled cpqHeCorrMemLogSta

Página 100

Appendix D: Insight SNMP rules 189 Trap name OID () Caused by Cleared by New in revision 5.0 CpqHeThermalDegradedAction:shutdown CpqHeThermal

Página 101

Appendix A: Troubleshooting and known issues 19 Appendix A: Troubleshooting and known issues Troubleshooting The following sections contain info

Página 102

Appendix D: Insight SNMP rules 190 Trap name OID () Caused by Cleared by New in revision 5.0 cpqHe4FltTolPowerSupplyACpowerloss 6069 — — —

Página 103

Appendix D: Insight SNMP rules 191 Trap name OID () Caused by Cleared by New in revision 5.0 CpqSsTempSensorStatus:failed CpqSsTempSensorSt

Página 104

Appendix D: Insight SNMP rules 192 Trap name OID () Caused by Cleared by New in revision 5.0 CpqSsBackplaneFtpsStatus:noFltTolPower CpqSsBac

Página 105

Appendix D: Insight SNMP rules 193 Trap name OID () Caused by Cleared by New in revision 5.0 CpqSsBoxFanStatus:failed CpqSsBoxFanStatus.3 —

Página 106

Appendix D: Insight SNMP rules 194 Trap name OID () Caused by Cleared by New in revision 5.0 CpqSsBoxFltTolPwrSupplyStatus:failed CpqSsBoxFl

Página 107

Appendix D: Insight SNMP rules 195 Threshold management (CPQTHRSH.MIB) Trap name OID () Caused by Cleared by New in revision 5.0 CpqMeRising

Página 108

Appendix D: Insight SNMP rules 196 Recovery server information (CPQRECOV.MIB) Trap name OID () Caused by Cleared by New in revision 5.0 CpqR

Página 109

Appendix D: Insight SNMP rules 197 Trap name OID () Caused by Cleared by New in revision 5.0 cpqClusterNodeCondition:failed cpqClusterNodeCon

Página 110

Appendix D: Insight SNMP rules 198 Trap name OID () Caused by Cleared by New in revision 5.0 CpqFcCntlrActive 16014 — — — CpqFca2PhyDrvSt

Página 111

Appendix D: Insight SNMP rules 199 Trap name OID () Caused by Cleared by New in revision 5.0 CpqFcaHostCntlrStatus:loopFailed CpqFcaHostCntlr

Página 112

© Copyright 2001, 2011 Hewlett-Packard Development Company, L.P. Confidential computer software. Valid license from HP required for possession, u

Página 113

Appendix B: HP SNMP events 20 Appendix B: HP SNMP events HP SNMP events The following tables list all of the HP ProLiant SNMP definitions delive

Página 114

Appendix D: Insight SNMP rules 200 Trap name OID () Caused by Cleared by New in revision 5.0 CpqFcTapeDriveStatus:missingWasOffline CpqFcTape

Página 115

Appendix D: Insight SNMP rules 201 Trap name OID () Caused by Cleared by New in revision 5.0 CpqNic3RedundancyIncreased 18013 — — — CpqNi

Página 116

Appendix D: Insight SNMP rules 202 Trap name OID () Caused by Cleared by New in revision 5.0 CpqRPMTrapCMCVoltNormal 10013 — — — CpqRPMT

Página 117

Appendix D: Insight SNMP rules 203 Trap name OID () Caused by Cleared by New in revision 5.0 cpqRPMTrapUPSOutputVoltageAboveMax 20012 — 21

Página 118

Appendix D: Insight SNMP rules 204 Trap name OID () Caused by Cleared by New in revision 5.0 cpqRPMTrapUPSBypassManualTurnedOff 20192 — —

Página 119

Appendix D: Insight SNMP rules 205 Trap name OID () Caused by Cleared by New in revision 5.0 cpqRPMtrapUPSBypassOnAutoCleared 21048 — — —

Página 120

Appendix D: Insight SNMP rules 206 Trap name OID () Caused by Cleared by New in revision 5.0 CpqRackEnclosureFanInserted 22012 — — — CpqR

Página 121

Appendix D: Insight SNMP rules 207 Trap name OID () Caused by Cleared by New in revision 5.0 CpqRackServerBladeRemoved 22028 — 22029 — Cp

Página 122

Appendix D: Insight SNMP rules 208 Trap name OID () Caused by Cleared by New in revision 5.0 cpqRackServerBladeUnexpectedShutdown 22056 — —

Página 123

Appendix D: Insight SNMP rules 209 Trap name OID () Caused by Cleared by New in revision 5.0 CpqCmcStatusTemp1:underMin CpqCmcStatusTemp.5 —

Página 124

Appendix B: HP SNMP events 21 Trap types Rules file Description Netcool severity cpqCrDiskAvailableTrap (13) 13 This event occurs when a disk

Página 125

Appendix D: Insight SNMP rules 210 Trap name OID () Caused by Cleared by New in revision 5.0 CpqCmcStatusFan2:smokeOff CpqCmcStatusFan2.6 —

Página 126

Appendix D: Insight SNMP rules 211 Trap name OID () Caused by Cleared by New in revision 5.0 CpqCmcStatusInput3:closed CpqCmcStatusInput3.2 —

Página 127

Appendix D: Insight SNMP rules 212 Trap name OID () Caused by Cleared by New in revision 5.0 CpqCmcStatusLock2Lock:unlockedTime CpqCmcStatusL

Página 128

Appendix D: Insight SNMP rules 213 Trap name OID () Caused by Cleared by New in revision 5.0 CpqCmcStatusAux2:ok CpqCmcStatusAux2.2 — — — C

Página 129

Appendix D: Insight SNMP rules 214 Trap name OID () Caused by Cleared by New in revision 5.0 CpqCmcStatusLock2Dev:notAvail CpqCmcStatusLock2D

Página 130

Appendix D: Insight SNMP rules 215 Trap name OID () Caused by Cleared by New in revision 5.0 cpqSwccFibreDevState:degraded cpqSwccFibreDevSta

Página 131

Appendix D: Insight SNMP rules 216 StorageWorks Enterprise Array Manager (HS_AGENT.MIB) Trap name OID () Caused by Cleared by New in revisio

Página 132

Appendix D: Insight SNMP rules 217 Trap name OID () Caused by Cleared by New in revision 5.0 bt2SwRackLocationChange 26 — — — bt2SwApplyC

Página 133

Appendix D: Insight SNMP rules 218 Trap name OID () Caused by Cleared by New in revision 5.0 cpqServiceIncidentStatus:closed cpqServiceIncide

Página 134

Appendix D: Insight SNMP rules 219 Trap name OID () Caused by Cleared by New in revision 5.0 cpqIoDrvInfoState: minimal cpqIoDrvInfoState.3

Página 135

Appendix B: HP SNMP events 22 Trap types Rules file Description Netcool severity cpqCrExpCabTemperatureCriticalTrap (27) 27 This event occurs

Página 136

Appendix D: Insight SNMP rules 220 Trap name OID () Caused by Cleared by New in revision 5.0 sCellEventTrap-03-0c 13600780 — — — sCellEve

Página 137

Appendix D: Insight SNMP rules 221 Trap name OID () Caused by Cleared by New in revision 5.0 sCellEventTrap-04-12 13601042 — — — sCellEve

Página 138

Appendix D: Insight SNMP rules 222 Trap name OID () Caused by Cleared by New in revision 5.0 sCellEventTrap-06-34 13601588 — — — sCellEve

Página 139

Appendix D: Insight SNMP rules 223 Trap name OID () Caused by Cleared by New in revision 5.0 sCellEventTrap-07-01 13601793 — — — sCellEve

Página 140

Appendix D: Insight SNMP rules 224 Trap name OID () Caused by Cleared by New in revision 5.0 sCellEventTrap-09-1e 13602334 — — — sCellEve

Página 141

Appendix D: Insight SNMP rules 225 Trap name OID () Caused by Cleared by New in revision 5.0 sCellEventTrap-09-46 13602374 — — — sCellEve

Página 142 - Previous Length

Appendix D: Insight SNMP rules 226 Trap name OID () Caused by Cleared by New in revision 5.0 sCellEventTrap-09-80 13602432 — — — sCellEve

Página 143

Appendix D: Insight SNMP rules 227 Trap name OID () Caused by Cleared by New in revision 5.0 sCellEventTrap-0c-0c 13603084 — — — sCellEve

Página 144

Appendix D: Insight SNMP rules 228 Trap name OID () Caused by Cleared by New in revision 5.0 sCellEventTrap-0c-38 13603128 — — — sCellEve

Página 145

Appendix D: Insight SNMP rules 229 Trap name OID () Caused by Cleared by New in revision 5.0 sCellEventTrap-0c-65 13603173 — — — sCellEve

Página 146

Appendix B: HP SNMP events 23 Trap types Rules file Description Netcool severity cpqSePCCardThermalDegraded (1002) 1002 This event occurs when

Página 147

Appendix D: Insight SNMP rules 230 Trap name OID () Caused by Cleared by New in revision 5.0 sCellEventTrap-0e-0a 13603594 — — — sCellEve

Página 148

Appendix D: Insight SNMP rules 231 Trap name OID () Caused by Cleared by New in revision 5.0 sCellEventTrap-0e-3c 13603644 — 13603589 13603

Página 149

Appendix D: Insight SNMP rules 232 Trap name OID () Caused by Cleared by New in revision 5.0 sCellEventTrap-42-0d 13616909 — — — sCellEve

Página 150

Appendix D: Insight SNMP rules 233 Trap name OID () Caused by Cleared by New in revision 5.0 mngmtAgentTrap-32 136000032 — — — mngmtAgent

Página 151

Appendix D: Insight SNMP rules 234 Trap name OID () Caused by Cleared by New in revision 5.0 mngmtAgentTrap-71 136000071 — — — mngmtAgent

Página 152

Appendix D: Insight SNMP rules 235 Trap name OID () Caused by Cleared by New in revision 5.0 mngmtAgentTrap-110 136000110 — — — mngmtAgen

Página 153

Appendix D: Insight SNMP rules 236 Trap name OID () Caused by Cleared by New in revision 5.0 mngmtAgentTrap-201 136000201 — — — mngmtAgen

Página 154

Appendix D: Insight SNMP rules 237 Trap name OID () Caused by Cleared by New in revision 5.0 mngmtAgentTrap-2004 136002004 — — — mngmtAge

Página 155

Appendix D: Insight SNMP rules 238 Trap name OID () Caused by Cleared by New in revision 5.0 mngmtAgentTrap-2065 136002065 — — — mngmtAge

Página 156

Appendix D: Insight SNMP rules 239 Trap name OID () Caused by Cleared by New in revision 5.0 mngmtAgentTrap-2106 136002106 — — — mngmtAge

Página 157

Appendix B: HP SNMP events 24 Trap types Rules file Description Netcool severity cpqSiMonitorConditionDegraded (2003) 2003 This event occurs w

Página 158

Appendix D: Insight SNMP rules 240 Trap name OID () Caused by Cleared by New in revision 5.0 mngmtAgentTrap-3056 136003056 — — — mngmtAge

Página 159 - Netcool

Appendix D: Insight SNMP rules 241 Trap name OID () Caused by Cleared by New in revision 5.0 mngmtAgentTrap-4012 136004012 — — — mngmtAge

Página 160 - (CPQSANAPP.MIB)

Appendix D: Insight SNMP rules 242 Trap name OID () Caused by Cleared by New in revision 5.0 mngmtAgentTrap-4078 136004078 — — — mngmtAge

Página 161

Appendix D: Insight SNMP rules 243 Trap name OID () Caused by Cleared by New in revision 5.0 mngmtAgentTrap-6021 136006021 — — — mngmtAge

Página 162

Appendix D: Insight SNMP rules 244 Trap name OID () Caused by Cleared by New in revision 5.0 mngmtAgentTrap-8022 136008022 — — — mngmtAge

Página 163

Appendix D: Insight SNMP rules 245 Trap name OID () Caused by Cleared by New in revision 5.0 mngmtAgentTrap-8061 136008061 — — — mngmtAge

Página 164

Appendix D: Insight SNMP rules 246 Trap name OID () Caused by Cleared by New in revision 5.0 mngmtAgentTrap-9001 136009001 — — — mngmtAge

Página 165

Appendix D: Insight SNMP rules 247 Trap name OID () Caused by Cleared by New in revision 5.0 mngmtAgentTrap-9041 136009041 — — — mngmtAge

Página 166

Appendix D: Insight SNMP rules 248 Trap name OID () Caused by Cleared by New in revision 5.0 mngmtAgentTrap-10050 136010050 — — — mngmtAg

Página 167

Appendix D: Insight SNMP rules 249 Trap name OID () Caused by Cleared by New in revision 5.0 mngmtAgentTrap-13003 136013003 — 136013002 —

Página 168

Appendix B: HP SNMP events 25 Trap types Rules file Description Netcool severity cpqSiSysBatteryFailure (2011) 2011 This event occurs when the

Página 169

Appendix D: Insight SNMP rules 250 Trap name OID () Caused by Cleared by New in revision 5.0 mngmtAgentTrap-16013 136016013 — — — mngmtAg

Página 170

Appendix D: Insight SNMP rules 251 Trap name OID () Caused by Cleared by New in revision 5.0 mngmtAgentTrap-17014 136017014 — — — mngmtAg

Página 171 - NSM-NOTIFICATION-MIB)

Appendix D: Insight SNMP rules 252 Trap name OID () Caused by Cleared by New in revision 5.0 mngmtAgentTrap-18051 136018051 — — — mngmtAg

Página 172

Appendix D: Insight SNMP rules 253 Trap name OID () Caused by Cleared by New in revision 5.0 mngmtAgentTrap-20032 136020032 — — — mngmtAg

Página 173

Appendix D: Insight SNMP rules 254 Trap name OID () Caused by Cleared by New in revision 5.0 mngmtAgentTrap-24004 136024004 — — — mngmtAg

Página 174

Appendix D: Insight SNMP rules 255 Trap name OID () Caused by Cleared by New in revision 5.0 mngmtAgentTrap-27001 136027001 — — — mngmtAg

Página 175 - Non-HP SNMP events

Appendix D: Insight SNMP rules 256 Trap name OID () Caused by Cleared by New in revision 5.0 mngmtAgentTrap-27040 136027040 — — — mngmtAg

Página 176

Appendix D: Insight SNMP rules 257 HP datacenter environmental observer (CPQDCEEO.MIB) Trap name OID () Caused by Cleared by New in revision

Página 177 - Insight SNMP rules

Appendix D: Insight SNMP rules 258 Trap name OID () Caused by Cleared by New in revision 5.0 internalMsgStatus:tooHigh internalMsgStatus .8 —

Página 178

Appendix D: Insight SNMP rules 259 Trap name OID () Caused by Cleared by New in revision 5.0 cpqWcrmInternalStatus:reset cpqWcrmInternalStatu

Página 179

Appendix B: HP SNMP events 26 Trap types Rules file Description Netcool severity CpqDaCntlrActive (3016) 3016 This event occurs when a backup

Página 180 - New in revision

Appendix D: Insight SNMP rules 260 HP Bladetype-4 Network MIBs (GbE2c-L2L3.MIB) Trap name OID () Caused by Cleared by New in revision 5.0 bn

Página 181

Appendix D: Insight SNMP rules 261 Trap name OID () Caused by Cleared by New in revision 5.0 bntSwFwDownloadFailure 30 — 29 — bntSwTempRe

Página 182

Appendix D: Insight SNMP rules 262 Trap name OID () Caused by Cleared by New in revision 5.0 bntSwCistTopologyChanged 45 — — — bntSFPInse

Página 183

Appendix D: Insight SNMP rules 263 LSI Logic SCSI Storage Adapters (SYMTRAP.MIB) Trap name OID () Caused by Cleared by New in revision 5.0 s

Página 184

Appendix D: Insight SNMP rules 264 Trap name OID () Caused by Cleared by New in revision 5.0 connUnitPortStatus:ready connUnitPortStatus.3 —

Página 185

Appendix D: Insight SNMP rules 265 LeftHand Networks notifications-MIB (LEFTHAND-NETWORKS-NSM-NOTIFICATION-MIB) Trap name OID () Caused by

Página 186

Appendix D: Insight SNMP rules 266 severity:warning severity.1 — — * severity:info severity.2 — — * lhnNsmNotificationPowerSupply 9 — — *

Página 187

Appendix D: Insight SNMP rules 267 severity:critical severity.0 — — * severity:warning severity.1 — — * severity:info severity.2 — — * lhn

Página 188

Acronyms and abbreviations 268 Acronyms and abbreviations ATA Advanced Technology Attachment CPU central processing unit IDE integrated device e

Página 189

Index 269 Index A about this guide, 6 alerts, 13 audience assumptions, 6 automated event correlation, 9 Automation, 11 B BT2TRAPS.MIB, 166, 223

Página 190

Appendix B: HP SNMP events 27 Trap types Rules file Description Netcool severity cpqDa5AccelBatteryFailed (3027) 3027 This event occurs when a

Página 191

Index 270 L lefthand-networks-nsm-notification-mib, 177, 274 Logical Network adapter status, 16 M Management Integration Support website, 6 mana

Página 192

Appendix B: HP SNMP events 28 Trap types Rules file Description Netcool severity CpqDaTapeDrvStatus:missingWasOffline CpqDaTapeDrvStatus.7 —

Página 193

Appendix B: HP SNMP events 29 Trap types Rules file Description Netcool severity CpqDaSpareStatus:failed CpqDaSpareStatus.3 — Critical (5)

Página 194

Contents 3 Contents About this guide ...

Página 195

Appendix B: HP SNMP events 30 Trap types Rules file Description Netcool severity CpqDaTapeLibraryDoorStatus:notSupported CpqDaTapeLibraryDoorS

Página 196

Appendix B: HP SNMP events 31 Trap types Rules file Description Netcool severity cpqDaCntlrPartnerBoardStatus:ok cpqDaCntlrPartnerBoardStatus.

Página 197

Appendix B: HP SNMP events 32 Trap types Rules file Description Netcool severity CpqTapeLibraryState:ok CpqTapeLibraryState .2 — Clear (0) Cp

Página 198

Appendix B: HP SNMP events 33 Trap types Rules file Description Netcool severity CpqScsiPhyDrvStatus:hardError CpqScsiPhyDrvStatus .12 — Majo

Página 199

Appendix B: HP SNMP events 34 Trap types Rules file Description Netcool severity cpqSasLogDrvStatusChange (5023) — This event occurs when the

Página 200

Appendix B: HP SNMP events 35 Trap types Rules file Description Netcool severity cpqHe3ThermalTempOk (6019) 6019 This event occurs when the s

Página 201

Appendix B: HP SNMP events 36 Trap types Rules file Description Netcool severity cpqHe3FltTolPowerSupplyInserted (6033) 6033 This event occurs

Página 202

Appendix B: HP SNMP events 37 Trap types Rules file Description Netcool severity cpqHe3PowerConverterRedundancyLost (6045) 6045 This event occ

Página 203

Appendix B: HP SNMP events 38 Trap types Rules file Description Netcool severity cpqHeResMemBoardRemoved (6057) 6057 This event occurs when an

Página 204

Appendix B: HP SNMP events 39 Storage systems information (CPQSTSYS.MIB) Trap types Rules file Description Netcool severity cpqSs3FanStatusCh

Página 205

Contents 4 Remote Insight board information (CPQSM2.MIB) ... 44

Página 206

Appendix B: HP SNMP events 40 Trap types Rules file Description Netcool severity CpqSsPowerSupplyUpsStatus:powerFailed CpqSsPowerSupplyUpsStat

Página 207

Appendix B: HP SNMP events 41 Trap types Rules file Description Netcool severity CpqSsBackplaneFanStatus:notSupported CpqSsBackplaneFanStatus.

Página 208

Appendix B: HP SNMP events 42 Trap types Rules file Description Netcool severity CpqSsChassisRsoStatus:daemonDownDisabled CpqSsChassisRsoStatu

Página 209

Appendix B: HP SNMP events 43 Trap types Rules file Description Netcool severity CpqSsBoxFltTolPwrSupplyStatus:ok CpqSsBoxFltTolPwrSupplyStatu

Página 210

Appendix B: HP SNMP events 44 Trap types Rules file Description Netcool severity cpqSsBoxConnectionStatus: connected cpqSsBoxConnectionStatus.

Página 211

Appendix B: HP SNMP events 45 Trap types Rules file Description Netcool severity cpqSm2ServerCritical (5)Error (9014) 9014 This event occurs w

Página 212

Appendix B: HP SNMP events 46 Trap types Rules file Description Netcool severity CpqHoSWRunningStatus:Warning CpqHoSWRunningStatus.3 — Minor

Página 213

Appendix B: HP SNMP events 47 Trap types Rules file Description Netcool severity cpqIdeDriveOk (14002) 14002 This event occurs when the IDE d

Página 214

Appendix B: HP SNMP events 48 Trap types Rules file Description Netcool severity CpqClusterResourceConditionChange (15005) — This event occurs

Página 215 - Switch Traps (CIMTRAPS.MIB)

Appendix B: HP SNMP events 49 Trap types Rules file Description Netcool severity CpqFcTapeCntlrStatus:offline CpqFcTapeCntlrStatus.3 — Major

Página 216

Contents 5 Fibre Channel array information (CPQFCA.MIB) ... 197

Página 217

Appendix B: HP SNMP events 50 Trap types Rules file Description Netcool severity cpqFca2HostCntlrStatusChange (16021) — This event occurs when

Página 218

Appendix B: HP SNMP events 51 Trap types Rules file Description Netcool severity CpqFcaLogDrvStatus:hardError CpqFcaLogDrvStatus.15 — Major (

Página 219

Appendix B: HP SNMP events 52 Trap types Rules file Description Netcool severity cpqFca3HostCntlrStatusChange (16028) — This event occurs when

Página 220

Appendix B: HP SNMP events 53 Trap types Rules file Description Netcool severity cpqNic3ConnectivityRestored (18011) 18011 This event occurs w

Página 221

Appendix B: HP SNMP events 54 Rack and power management (CPQRPM.MIB) Trap types Rules file Description Netcool severity cpqRPMTrapDeviceConne

Página 222

Appendix B: HP SNMP events 55 Trap types Rules file Description Netcool severity CpqRPMTrapCMCHmdtOver(10022) 10022 This event occurs when a C

Página 223

Appendix B: HP SNMP events 56 Trap types Rules file Description Netcool severity cpqRPMTrapCMCLockset1Locked(10114) 10114 This event occurs wh

Página 224

Appendix B: HP SNMP events 57 Trap types Rules file Description Netcool severity cpqRPMTrapUPSInternalFailure (20111) 20111 This event occurs

Página 225

Appendix B: HP SNMP events 58 Trap types Rules file Description Netcool severity cpqRPMtrapUPSTemperatureOutOfRange (21007) 21007 This event o

Página 226

Appendix B: HP SNMP events 59 Trap types Rules file Description Netcool severity cpqRPMTrapUPSCheckBreaker (21041) 21041 This event occurs whe

Página 227

About this guide 6 About this guide Intended audience This book is intended for anyone who needs to use Netcool/OMNIbus desktop tools on UNIX or

Página 228

Appendix B: HP SNMP events 60 Trap types Rules file Description Netcool severity cpqPMTrapCritical (1) 1 This event occurs when a Critical al

Página 229

Appendix B: HP SNMP events 61 Trap types Rules file Description Netcool severity cpqRackPowerSupplyFailed (22013) 22013 This event occurs when

Página 230

Appendix B: HP SNMP events 62 Trap types Rules file Description Netcool severity cpqRackServerPowerOnFailedEnclosureNotFound (22024) 22024 Thi

Página 231

Appendix B: HP SNMP events 63 Trap types Rules file Description Netcool severity cpqRackEnclosureManagerOk (22038) 22038 This event occurs whe

Página 232

Appendix B: HP SNMP events 64 Trap types Rules file Description Netcool severity cpqRackServerBladeGrpCapTimeout(22055) 22055 This event occur

Página 233

Appendix B: HP SNMP events 65 Trap types Rules file Description Netcool severity cpqRackServerBladePoweredOff(22070) 22070 This event occurs w

Página 234

Appendix B: HP SNMP events 66 Trap types Rules file Description Netcool severity CpqCmcStatusTemp2:overMax CpqCmcStatusTemp2.4 — Major (4) Cp

Página 235

Appendix B: HP SNMP events 67 Trap types Rules file Description Netcool severity CpqCmcStatusHumidity:normal CpqCmcStatusHumidity.2 — Clear (

Página 236

Appendix B: HP SNMP events 68 Trap types Rules file Description Netcool severity cpqCmcalarmLock1 (153011) — This event occurs when there is

Página 237

Appendix B: HP SNMP events 69 Trap types Rules file Description Netcool severity CpqCmcStatusLock2Lock:unlockedNetFail CpqCmcStatusLock2Lock9

Página 238

Product overview 7 Product overview Product description HP Insight integration module for Netcool/OMNIbus is a comprehensive solution that provi

Página 239

Appendix B: HP SNMP events 70 Trap types Rules file Description Netcool severity CpqCmcStatusAux2:noSensor CpqCmcStatusAux2.4 — Minor (3) cpq

Página 240

Appendix B: HP SNMP events 71 Trap types Rules file Description Netcool severity CpqCmcStatusLock2Dev:noConnect CpqCmcStatusLock2Dev.7 — Mino

Página 241

Appendix B: HP SNMP events 72 Trap types Rules file Description Netcool severity switchCubeTypeChange (161014) 161014 This event occurs when t

Página 242

Appendix B: HP SNMP events 73 Trap types Rules file Description Netcool severity cpqServiceIncidentStatus:delivered cpqServiceIncidentStatus.3

Página 243

Appendix B: HP SNMP events 74 Trap types Rules file Description Netcool severity 02(13600258) change sCellEventTrap-03-01(13600769) 136007

Página 244

Appendix B: HP SNMP events 75 Trap types Rules file Description Netcool severity 12(13600786) operation is completed. sCellEventTrap-03-13(1

Página 245

Appendix B: HP SNMP events 76 Trap types Rules file Description Netcool severity from another HSV300 controller prior to it terminating the o

Página 246

Appendix B: HP SNMP events 77 Trap types Rules file Description Netcool severity is the Storage System Master. sCellEventTrap-04-10(13601040)

Página 247

Appendix B: HP SNMP events 78 Trap types Rules file Description Netcool severity respond. sCellEventTrap-06-02(13601538) 13601538 This event

Página 248

Appendix B: HP SNMP events 79 Trap types Rules file Description Netcool severity 1f(13601567) one port is corrected and redundancy is restor

Página 249

Product overview 8 HP hardware support The HP Insight Integration module for Netcool/OMNIbus has been developed to install and operate with Netc

Página 250

Appendix B: HP SNMP events 80 Trap types Rules file Description Netcool severity 36(13601590) firmware revision is detected by the physical

Página 251

Appendix B: HP SNMP events 81 Trap types Rules file Description Netcool severity 50(13601616) Module has completed updating its code. It is

Página 252

Appendix B: HP SNMP events 82 Trap types Rules file Description Netcool severity sCellEventTrap-06-5d(13601629) 13601629 This event occurs wh

Página 253

Appendix B: HP SNMP events 83 Trap types Rules file Description Netcool severity in the Disk Group caused by the failure or pulling of a phys

Página 254

Appendix B: HP SNMP events 84 Trap types Rules file Description Netcool severity 02(13602306) volume has changed. sCellEventTrap-09-03(13602

Página 255

Appendix B: HP SNMP events 85 Trap types Rules file Description Netcool severity normal operating range. sCellEventTrap-09-17(13602327) 13602

Página 256

Appendix B: HP SNMP events 86 Trap types Rules file Description Netcool severity removed from the power supply. sCellEventTrap-09-29(13602345

Página 257

Appendix B: HP SNMP events 87 Trap types Rules file Description Netcool severity sCellEventTrap-09-3a(13602362) 13602362 This event occurs wh

Página 258

Appendix B: HP SNMP events 88 Trap types Rules file Description Netcool severity sCellEventTrap-09-50(13602384) 13602384 This event occurs wh

Página 259

Appendix B: HP SNMP events 89 Trap types Rules file Description Netcool severity changes. sCellEventTrap-09-77(13602423) 13602423 This event

Página 260

Product overview 9 • HP Tru64 UNIX 5.1A and later • HP OpenVMS 7.1 and later • UnixWare 7 or later and Open UNIX 8 • Linux ○ Red Hat ○ SUS

Página 261

Appendix B: HP SNMP events 90 Trap types Rules file Description Netcool severity sCellEventTrap-09-cd(13602509) 13602509 This event occurs wh

Página 262

Appendix B: HP SNMP events 91 Trap types Rules file Description Netcool severity db(13602523) controller blower 2 is running at normal speed

Página 263

Appendix B: HP SNMP events 92 Trap types Rules file Description Netcool severity 07(13603079) terminated prior to completion. A remote copy

Página 264

Appendix B: HP SNMP events 93 Trap types Rules file Description Netcool severity Replication Group that is failsafe mode disabled. sCellEvent

Página 265

Appendix B: HP SNMP events 94 Trap types Rules file Description Netcool severity preventing replication processing for the specified Data Rep

Página 266

Appendix B: HP SNMP events 95 Trap types Rules file Description Netcool severity 2c(13603116) operation on the Data Replication Source Stora

Página 267

Appendix B: HP SNMP events 96 Trap types Rules file Description Netcool severity between the specified host port and the Peer Storage System.

Página 268 - Acronyms and abbreviations

Appendix B: HP SNMP events 97 Trap types Rules file Description Netcool severity sCellEventTrap-0c-40(13603136) 13603136 This event occurs wh

Página 269

Appendix B: HP SNMP events 98 Trap types Rules file Description Netcool severity because the requested protocol version is not compatible wit

Página 270

Appendix B: HP SNMP events 99 Trap types Rules file Description Netcool severity sCellEventTrap-0c-5f(13603167) 13603167 This event occurs wh