Appendix B: HP SNMP events 34
Trap types Rules file Description
Netcool
severity
cpqSasLogDrvStatusChange
(5023)
—
This event occurs when the status
of a SAS or SATA logical drive
changes.
—
CpqSasLogDrvStatus:ok
CpqSasLogDrvStatus.
2
— Clear (0)
CpqSasLogDrvStatus:degraded
CpqSasLogDrvStatus.
3
— Minor (3)
CpqSasLogDrvStatus:rebuilding
CpqSasLogDrvStatus.
4
— Minor (3)
CpqSasLogDrvStatus:failed
CpqSasLogDrvStatus.
5
— Critical (5)
CpqSasLogDrvStatus:offline
CpqSasLogDrvStatus.
6
— Critical (5)
CpqSas2TapeDrvStatusChange
(5025)
—
This event occurs when the status
of a SAS tape drive changes.
—
cpqSasTapeDrvStatus: ok
cpqSasTapeDrvStatus
.2
— Clear (0)
cpqSasTapeDrvStatus: offline
cpqSasTapeDrvStatus
.3
— Critical (5)
Server health features (CPQHLTH.MIB)
Trap types Rules file Description
Netcool
severity
cpqHe3CorrectableMemoryLogD
isabled (6016)
—
This event occurs when the
frequency of correctable memory
errors is so high that the error
tracking logic has been
temporarily disabled.
—
cpqHeCorrMemLogStatus:notSup
ported
cpqHeCorrMemLogSt
atus.2
— Minor (3)
cpqHeCorrMemLogStatus:disabl
ed
cpqHeCorrMemLogSt
atus.3
— Major (4)
cpqHeCorrMemLogStatus:enable
d
cpqHeCorrMemLogSt
atus.4
— Clear (0)
cpqHe3ThermalTempFailed
(6017)
6017
This event occurs when the
temperature status has been set to
fail.
Critical (5)
cpqHe3ThermalTempDegraded
(6018)
—
This event occurs when the server's
temperature is outside of the
normal operating range.
—
cpqHeThermalDegradedAction:c
ontinue
cpqHeThermalDegra
dedAction.2
— Major (4)
cpqHeThermalDegradedAction:s
hutdown
cpqHeThermalDegra
dedAction.3
— Major (4)