HP NAS 8000 Clustered Solution Manual do Utilizador Página 72

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 240
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 71
70 Configuring Your System and Network
Configuring Alert Settings
Defining SNMP Alerts
If you are using a network management product such as HP OpenView, CA
Unicenter, or Tivoli Network Node Manager, you can define the names of
management workstations to receive notification in case of a failure. For more
information about these products, see the
HP Surestore Enterprise Integrations
Installation and User Guide
at http://www.hp.com/support/emsp.
Note The information on this screen is optional. Blank fields do not
affect the functionality of the device. In the event of a hardware
failure or system alert, messages are sent through SMTP (email),
or they are logged in the system log.
To define the management servers to notify:
1 In the Command View NAS web interface, click the Configuration tab.
2 Navigate down the tree to Alerts/Logging, then select SNMP Alerts.
3 Select Actions > Edit SNMP Settings.
4 Enter the SNMP password required for network management tools to
retrieve operational or configuration information from the device in the
SNMP Community String field.
5 Enter the name or IP address of the server you want the system to notify in
the SNMP Trap Destinations field.
6 Click OK.
To edit the Trap Destinations, click Actions > Edit SNMP settings, then:
Click the incorrect entry to modify it.
Click the entry and click the delete icon to remove it.
Click OK to apply each change.
See Appendix B, SNMP Trap Definitions for a list of the traps sent by the NAS
server.
Vista de página 71
1 2 ... 67 68 69 70 71 72 73 74 75 76 77 ... 239 240

Comentários a estes Manuais

Sem comentários