Hp Array Controller HSG V8.7 Software Manual do Utilizador Página 134

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 206
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 133
Power Distribution
6–8 UltraSCSI RAID Enclosure
Any one of the following power related error conditions will cause
this UltraSCSI RAID enclosure to cease operation:
Loss of the ac power source
•Failure of two shelf power supplies
Failure of the ac input box
Redundant (n+4) Power Supply
Configurations
This power configuration provides more power redundancy than the
standard configuration. AC power distribution is provided over both
power buses (A and B, CALLOUTS 1 and 2, respectively) as shown in
Figure 6–6. Each bus has four power supplies for a total of eight.
Figure 66 Redundant Power Configuration
AC input box A distributes the ac power through four black cords at
the left side of the enclosure. AC input box B distributes the ac power
through four grey cords on the right side of the enclosure.
Figure C
ALLOUTS
1. Power bus A
2. Power bus B
CXO5797A
17
11
CXO6482B
19 20 21 22 23 24
13 14 15 16 18
78910 12
123456
Controller A
Controller B
EMU
PVA
Cache B Cache A
AB
4A
3A
2A
1A
3B
2B
1B
4B
Shelf 4
Shelf 3
Shelf 2
Shelf 1
1
2
Vista de página 133
1 2 ... 129 130 131 132 133 134 135 136 137 138 139 ... 205 206

Comentários a estes Manuais

Sem comentários