Storage Devices
UltraSCSI RAID Enclosure 7–11
6. If there are no expansion enclosures, go to step 7.
If there are expansion
enclosures, turn O
FF
all the
ac input boxes for each
expansion enclosure by
pressing
O
on each ac power
switch (C
ALLOUT
1).
7. Turn O
FF
all the ac input
boxes for the master
enclosure by pressing
O
on
each ac power switch
(C
ALLOUT
1).
8. Press the disk drive SBB mounting tabs together to release the SBB.
9. Use both hands and pull
the disk drive SBB out
of the shelf.
10. Place the disk drive SBB into an electrostatic bag.