Configuring the Switch
140 Edge Switch Element Manager User Guide
Figure 46: New Threshold Alerts dialog box - second screen
6. Enter a percentage from 1 through 100 for % utilization. When throughput
reaches this percentage of port capacity, a threshold alert will occur.
7. Enter the amount of cumulative minutes in which the % utilization should
exist during the notification interval before an alert is generated. You can also
click At any time if you want an alert to occur whenever the set % utilization
is reached. The valid range is 1 to the interval set in step 8.
8. Enter the interval in minutes in which throughput is measured and threshold
notifications can occur. The valid range is 5 minutes to 70,560 minutes.
9. Click Next. A new screen displays for choosing ports for the alerts, as shown
in Figure 47.