Monitoring and Managing the Switch
94 Edge Switch Element Manager User Guide
Not
Operational
Off Off Yellow
Triangle
The switch port is receiving the Fibre
Channel not operational sequence
(NOS) indicating that the attached
device is not operational.
Online On Off None The attached device has successfully
connected to the switch and is ready to
communicate or is in the process of
communicating with other attached
devices. As long as the port remains in
the online state, the green/blue port
LED remains illuminated. Note that on
the actual port in the unit, the
green/blue LED blinks when there is
active Fibre Channel traffic through the
port.
Offline Off Off None The switch port was configured as
“blocked” and is transmitting the Fibre
Channel OLS to the attached device.
Off Off Yellow
Triangle
The switch port was configured as
“Unblocked” and is receiving the Fibre
Channel OLS, indicating that the
attached device is offline.
Port Failure Off On Red and
Yellow
Blinking
Diamond
The switch port has failed and requires
service. The amber LED for the port
remains illuminated.
Segmented
E_Port
On Off Yellow
Triangle
The E_Port is segmented preventing the
two fabrics from joining (this only
occurs when two switches are
connected to each other). Display the
Port Properties dialog box to view the
segmentation reason.