Hp StorageWorks XP Remote Web Console Software Manual do Utilizador Página 204

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 203
Path Status
Description Corrective Action
Port Number
Mismatch
The specied port number
is not correct, or the cable
is not connected to the
specied port.
Delete the error path.
Check the specied port number or cable connections,
and then retry the operation.
Communicatio
n
Error
Atimeout erro
rhas occurred
in the bre pat
hbetween
the local and
remote storage
systems.
Delete the failed path and retry.
Logical Blockade
A failure occurs at a local
storage system port.
Repair the port status on the local storage system.
A failure occurs at a remote
storage system port.
Repair the port status on the remote storage system. After
that, delete the path by using the Delete Path or Delete
DKC command, and then add the path and the remote
storage system again by using the Add Path or Add DKC
command.
Afailure o
ccurs in the path
relay equi
pment.
Repair the
path relay equipment. After that, delete the
path by usi
ng the Delete Path or Delete DKC command,
and then a
dd thepathand theremotestorage system
again by u
sing the Add Path or Add DKC command.
The connection cable is
physically broken.
Replace the broken cable. After that, delete the path by
using the Delete Path or Delete DKC command, and then
add the path and the remote storage system again by
using the Add Path or Add DKC command.
Program Error
Program error is detected. Delete the path by using the Delete Path or Delete DKC
command, and then add the path and the remote storage
system again by using the Add Path or Add DKC command.
Table 33 Troubleshooting Suspended URz Pairs
Sus-
pend
Type
Applies
to
Description Corrective Action
Sec-
ondary
Data
Volume
by Op-
erator
Primary
data vol-
ume,
sec-
ondary
data vol-
ume
Theusersuspended thepairfromthe
primary or the secondary storage system by
using the secondary data volume option.
Restorethe pair from theprimary
storage system.
by RCU
Primary
data
volume
The primary storage system suspended a
pair because the primary storage system
detected an error condition at the secondary
storage system.
Clearthe errorcondition at the
secondary storage system or
sec
ondary data volume. If you need
to a
ccess the secondary data volume,
re
lease the pair from the secondary
st
orage system. If any data on the
se
condary data volume has changed,
release the pair from the primary
storage system and then re-create
t
he pair (Add Pair). If data on the
secondary data volume has not
changed, restore the pair from the
primary storage system.
204
Troubleshooting