Table 24 Path Status and Examples of Recovery Procedure (For TagmaStore AMS
Storage System, TagmaStore WMS Storage System)
Path Status
Examples of Recovery Procedure
External device setting
changed
Settings of the LU paths may have been changed by LUN Manager.
Check the setti
ngs of the LU paths. If the settings of the LU paths have been
changed, chang
e the settings back to the ones when the volume is mapped.
Or use External Storage to perform the Delete LU operation and perform
the Add LU operation again.
The access att
ribute of the volume may have been changed by HP
StorageWork
s XP Data Retention Utility.
Check the access attribute of the volume. If the volume is protected by the
access attribute, release the protection.
Illegal request or
Response error
The volume may have been set as a pair volume for data copy.
Check if the volume is set as a pair volume of Business Copy, Continuous
Access or some other copy program. If the volume is set as a pair volume,
the volume may be protected because of the pair status. When the volume is
protected, change the pair status or delete the pair.
The access attribute of the volume may have been changed by Data Retention
Utility.
Check the access attribute of the volume. If the volume is protected by the
access attribute, release the protection.
Cannotdetectport
There is a problem with connection to the external storage system. The
following are possible causes:
The bre cable is not physically connected in the proper way.
The setting of the topology does not match between the external port
and the target port.
If the external storage system is connected through switches, the settings
for the switches may not be appropriate.
Check if the bre cable is connected properly, and then set the Fibre Channel
port properly using LUN Manager.
Thehostgroup security mayhavebeenenabled by LUN Manager.
Check if the host group security is enabled or not. If the host group security is
enabled, disable the host group security.
Thunder 9500V Storage System
System Parameters for Connecting Thunder 9500V Storage System
The table below explains whether to specify system parameters when making settings on ports on the
Thunder 9500V storage system.
11 6
Connecting External Storage Systems