Troubleshooting
151HP StorageWorks MSL5000 and MSL6000 Series Tape Libraries User Guide
3051 No Cartridges In Library
(No cartridge available for diag to run.)
■ Press the Enter button to clear the
message.
■ Insert cartridge.
■ Invalid user initiated operation. Set
parameters correctly and try again.
3052 Too Many Cartridges
(Unable to run cartridge or drive cycle
because loader is full with cartridges.)
■ Press the Enter button to clear the
message.
■ Remove a tape from the library.
■ Invalid user initiated operation. Set
parameters correctly and try again.
3054 Need 1 Drive Minimum
(No available drive to run diag.)
■ Install or activate a drive.
■ Press the Enter button to clear the
message.
■ Invalid user initiated operation. Set
parameters correctly and try again.
3057 Invalid Magazine Type
(Unsupported magazine type detected.)
■ Upgrade firmware if a newer revision
exists.
■ Press the Enter button to clear the
message.
■ Invalid user initiated operation. Set
parameters correctly and try again.
3058 Magazine Type Change Not
Handled
(Unsupported magazine type detected.)
■ Upgrade firmware if a newer revision
exists.
■ Press the Enter button to clear the
message.
■ Invalid user initiated operation. Set
parameters correctly and try again.
3059 Drive Type Not Supported
(Unsupported magazine type detected.)
■ Upgrade firmware if a newer revision
exists.
■ Press the Enter button to clear the
message.
■ Invalid user initiated operation. Set
parameters correctly and try again.
Table 11: Fault Symptom Codes (Continued)