HP MSL5026 Manual do Utilizador Página 154

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 153
Troubleshooting
154 HP StorageWorks MSL5000 and MSL6000 Series Tape Libraries User Guide
3078 Diag get drive 0 status failed
(Failed to get drive status, communication
error.)
Press the Enter button to reboot.
Ensure the drive shows good status
through the drive status window.
Deactivate the drive using the GUI control
panel maintenance menu.
Reseat drive.
Load/unload a cartridge to the drive to
verify.
Check the tape cartridge used in the last
operation for damage.
Run the cartridge cycle diagnostic to
verify.
3079 Diag get drive 1 status failed
(Failed to get drive status, communication
error.)
Press the Enter button to reboot.
Ensure the drive shows good status
through the drive status window.
Deactivate the drive using the GUI control
panel maintenance menu.
Reseat drive.
Load/unload a cartridge to the drive to
verify.
Check the tape cartridge used in the last
operation for damage.
Run the cartridge cycle diagnostic to
verify.
307A Diag get drive 2 status failed
(Failed to get drive status, communication
error.)
Press the Enter button to reboot.
Ensure the drive shows good status
through the drive status window.
Deactivate the drive using the GUI control
panel maintenance menu.
Reseat drive.
Load/unload a cartridge to the drive to
verify.
Check the tape cartridge used in the last
operation for damage.
Run the cartridge cycle diagnostic to
verify.
Table 11: Fault Symptom Codes (Continued)
FSC Message ERP
Vista de página 153
1 2 ... 149 150 151 152 153 154 155 156 157 158 159 ... 215 216

Comentários a estes Manuais

Sem comentários