8
RJ45 crimping
pliers
Multimeter
Network cable
tester
Mark pen
ESD-preventive
wrist strap
NOTE:
No installation tool or ESD-preventive wrist strap is provided with the firewall. Prepare them yourself.
Accessories supplied by the firewall
Console cable Grounding cable Feet Mounting bracket
Checklist before installation
Table 7 Checklist before installation
Item Requirements Result
Ventilation
• There is a minimum clearance of 10 cm (3.9 in) around
the inlet and exhaust vents for heat dissipation of the
firewall chassis.
• A ventilation system is available at the installation site.
Operating
temperature
0°C to 45°C (32°F to 113°F)
Operating
humidity
5% to 95%
Cleanness Dust concentration 3 × 10
4
particles/m
3
Installation site
ESD prevention
• The equipment and floor are well grounded.
• The equipment room is dust-proof.
• The humidity and temperature are at a proper level,
respectively.
• Wear an ESD-preventive wrist strap and uniform when
touching a circuit board.
• Place the removed interface module on an antistatic
workbench, with the face upward, or put it into an
antistatic bag.
• Touch only the edges, instead of electronic components
when observing or moving a removed interface module.