Capstone Turbine Corporation 21211 Nordhoff Street Chatsworth CA 91311 USA
Product Specification: Model C200 - Capstone MicroTurbine
460045 Rev C (November 2008) Page 13 of 16
Capstone reserves the right to change or modify, without notice, the design, specifications, and/or contents of this document
without incurring any obligation either with respect to equipment previously sold or in the process of construction.
Acoustic Emissions Ratings at Full Load Power
Table 8 presents nominal acoustic emissions ratings, captured at full rated output power at a
distance of 10 meters (33 feet).
Actual sound levels for a given installation depend on many
site factors, so the numbers provided here should only be used as general guidance.
Table 8. Acoustic Emissions Ratings
Parameter
All C200
Acoustic Emissions
(1)
65 dBA
Note:
(1) Average of acoustic emissions measurements taken 10 meters from all sides at a height of 1.4 meters.
MicroTurbine Dimensions and Weights
Table 9 summarizes approximate dimensions and weights of the C200 MicroTurbine
systems.
Table 9. MicroTurbine Dimensions and Weights
Parameter
C200 Low Pressure
Natural Gas
All Other C200
Height
(1)
2,490 mm
(98 inches)
2,490 mm
(98 inches)
Width
1,700 mm
(67 inches)
1,700 mm
(67 inches)
Depth
3,660 mm
(144 inches)
3,660 mm
(144 inches)
Weight
2,730 kg (6,000 lb)
(Grid Connect)
3,640 kg (8,000 lb)
(Dual Mode)
2,270 kg (5,000 lb)
(Grid Connect)
3,180 kg (7,000 lb)
(Dual Mode)
Notes:
(1) Height dimensions are to the roof line. Exhaust outlet extends at least 8 inches above the roof line. Rear roof
extension and exhaust outlet can be removed to provide 88 inch height for shipment, if needed.
MicroTurbine Temperature Ratings
Table 10 summarizes the temperature ratings of MicroTurbine systems. The C200 must be
stored dry. For C200 systems with external heat recovery, minimum operating temperature
depends on heat recovery fluid characteristics.
Table 10. MicroTurbine Temperature Ratings
Parameter C200
Operating Temperature
-20 to 50 °C (-4 to 122 °F)
Storage Temperature
-40 to 65 °C (-40 to 149 °F)