Vista de página 5
Capstone Turbine Corporation 21211 Nordhoff Street Chatsworth CA 91311 USA
Product Specification: Model C200 - Capstone MicroTurbine
460045 Rev C (November 2008) Page 6 of 16
Capstone reserves the right to change or modify, without notice, the design, specifications, and/or contents of this document
without incurring any obligation either with respect to equipment previously sold or in the process of construction.
Table 4 presents the electrical performance ratings for C200 MicroTurbines operating in the
Stand Alone mode at ISO conditions.
Table 4. Electrical Performance Ratings in Stand Alone Mode
Parameter C200 Low Pressure NG All Other C200
Net Power Output
190 (+0/- 4) kW 200 (+0/- 4) kW
Max Apparent Power Output
(1)
258 kVA at 480 VAC 258 kVA at 480 VAC
Nominal Voltage Operating Range
400 to 480 VAC 400 to 480 VAC
Frequency Operating Range
10 to 60 Hz 10 to 60 Hz
Output Voltage Connection
(2)
3-phase, 4 wire wye 3-phase, 4 wire wye
Max Output Current
(3)
310 Amps RMS
steady state
310 Amps RMS
steady state
Voltage THD
IEEE 519 Compliant, 5% IEEE 519 Compliant, 5%
Notes:
(1) System power factor is limited by maximum current in Stand Alone mode
(2) Neutral must be solidly grounded
(3) Values assume linear load
Performance Derating
Performance is affected by ambient temperature and elevation. The performance ratings
listed above are at full load power at ISO conditions. Performance derating occurs at ambient
temperatures and elevations above ISO conditions and is also affected by air inlet pressure,
back pressure, and system parasitic loads (e.g. fuel gas compressor, battery charging).
Typical derating curves for power output and efficiency based on ambient temperature are
shown in the curves on the following pages. These curves assume no external parasitic loads
no inlet air restrictions, and no exhaust back pressure.