QuickSpecs
HP DL380z Generation9 (Gen9) Virtual Workstation
Technical Specifications
c04484636 DA 15119 Worldwide Version 2 January 28, 2015
Page 38
System Unit
Dimensions
3.44 x 17.54 x 26.75 in (8.73 x 44.55 x 67.94 cm)
NOTE: Dimensions without Bezel
Weight
(approximate)
Minimum:
(Minimum - 8SFF chassis with 1xSFF HDD and
7 HDD blanks, 1x processor, 1x power supply
(plus blank), 1x Flexible Smart Array, 1x Riser
installed)
40.88 lb (18.54 kg)
Maximum:
(Maximum - 24 SFF hard drives (No rear
drives), 2x processors, 2x power supplies, 1x
Flexible Smart Array, 2x Risers installed)
49.71 lb (22.54 kg)
Input
Requirements
(per power supply)
Range Line Voltage
100 to 120 VAC
200 to 240 VAC
BTU Rating
Maximum
For 800W Power Supply: 3207 BTU/hr (at 100 VAC), 3071 BTU/hr (at
200 VAC), 3112 BTU/hr (at 240 VAC) for China Only
For 500W Power Supply: 1979 BTU/hr (at 100 VAC), 1911 BTU/hr (at
200 VAC), 1965 BTU/hr (at 240 VAC) for China Only
Power Supply
Output
(per power supply)
Rated Steady-State
Power
For 1400W Power Supply: 1400W (at 100 VAC), 1400W (at 240 VAC),
1400W (at 240 VAC)
For 800W Power Supply: 800W (at 100 VAC), 800W (at 240 VAC),
800W (at 240 VAC) input for China only
For 500W Power Supply: 500W (at 100 VAC), 500W (at 240 VAC),
500W (at 240 VAC) input for China only
Maximum Peak
Power
For 1400W Power Supply: 1400W (at 100 to 127 VAC), 1400W (at 200
to 240 1VAC), 1400W (at 240 VAC) input for China only
For 800W Power Supply: 800W (at 100 to 127 VAC), 800W (at 200 to
240 1VAC), 800W (at 240 VAC) input for China only
For 500W Power Supply: 500W (at 100 to 127 VAC), 500W (at 200 to
240 VAC), 500W (at 240 VAC) input for China only
System Inlet
Temperature
Standard Operating
Support
10° to 35°C (50° to 95°F) at sea level with an altitude derating of 1.0°C
per every 305 m (1.8°F per every 1000 ft) above sea level to a
maximum of 3050 m (10,000 ft), no direct sustained sunlight.
Maximum rate of change is 20°C/hr (36°F/hr). The upper limit and rate
of change may be limited by the type and number of options installed.
For approved hardware configurations, the supported system inlet
range is extended to be: 5° to 40°C (41° to 104°F) at sea level with an
altitude derating of 1.0°C per every 175 m (1.8°F per every 574 ft)
above 900 m (2953 ft) to a maximum of 3050 m (10,000 ft). The
approved hardware configurations for this system are listed at the
URL:www.hp.com/go/proliant/Ashrae For approved hardware
configurations, the supported system inlet range is extended to be: 5°
to 45°C (41° to 113°F) at sea level with an altitude derating of 1.0°C per
every 125 m (1.8°F per every 410 ft) above 900 m (2953 ft) to a
maximum of 3050 m (10,000 ft). The approved hardware
configurations for this system are listed at the URL:
www.hp.com/go/proliant/Ashrae
Extended Ambient
Operating Support
Non-operating
-30° to 60°C (-22° to 140°F). Maximum rate of change is 20°C/hr
(36°F/hr).
Relative Humidity
Operating
Minimum to be the higher (more moisture) of -12°C (10.4°F) dew point
or 8% relative humidity. Maximum to be the lower (less moisture) of
24°C (75.2°F) dew point or 90% relative humidity.