HP DL380z Generation9 (Gen9) Virtual Workstation
c04484636 — DA – 15119 Worldwide — Version 2 — January 28, 2015
5 to 95% relative humidity (Rh), 38.7°C (101.7°F) maximum wet bulb
temperature, non-condensing.
3050 m (10,000 ft). This value may be limited by the type and number
of options installed. Maximum allowable altitude change rate is 457
m/min (1500 ft/min).
9144 m (30,000 ft). Maximum allowable altitude change rate is 457
m/min (1500 ft/min).
Listed are the declared A-Weighted sound power levels (LWAd) and declared average
bystander position A-Weighted sound pressure levels (LpAm) when the product is operating
in a 23°C ambient environment. Noise emissions were measured in accordance with ISO 7779
(ECMA 74) and declared in accordance with ISO 9296 (ECMA 109).
NOTE: The Listed sound levels apply to standard shipping configurations (Entry, Base, and
Performance models) Additional options may result in increased sound levels. All models
above include the standard fans.
Emissions
Classification
(EMC)
CISPR 22; EN55022; EN55024; FCC CFR 47, Pt 15; ICES-003; CNS13438;
GB9254; K22;K24; EN 61000-3-2; EN 61000-3-3; EN 60950-1; IEC
60950-1
NOTE: Product conformance to cited product specifications is based on sample (type) testing,
evaluation, or assessment. This product or family of products is eligible to bear the
appropriate compliance logos and statements.
NOTE: The Listed sound levels apply to standard shipping configurations. Additional options
may result in increased sound levels.
HP Dynamic Smart
Array B140i
Controller
SAS/SATA peak
data transfer rate
2x4 connectors; 2x1 connectors