4–14 HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Troubleshooting
BMC Faults
BMC firmware is damaged Turn off and unplug the
system. Wait 20
seconds, then plug in
and restart the system. If
the error repeats,
replace the system
board.
System board FRU inventory
device inaccessible
Replace the system
board.
Temperature Faults
External air temperature too
high
Make sure nothing is
blocking the system’s
airflow and locate your
system in an
air-conditioned room.
Power Supply Errors
VRM or power pod fault
View the SEL for
additional information
(page D-4). For more
help, contact your HP
Support Engineer.
Power Supply 1 fault
Power Supply 2 fault
Replace the power
supply.
12V out of range (power supply
interface fault)
System
LED LED1 LED2 LED3 LED4 Problem Solution