D–2 HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Event, Error and Warning Messages
22 Error reading BMC token on upload to
NVM
—
23 Error reading BMC first boot token —
24 Primary FIT failed Reflash firmware
25 Secondary FIT failed Reflash firmware
26 PAL_A warning. One copy of PAL is bad Reflash firmware
27 PAL_B warning. Not compatible with at
least one CPU
Update firmware
28 Memory errors detected and PDT is
disabled
Reseat DIMMs, if error persists
replace bad DIMMs
30 Memory required reinterleave to get a
good page 0
—
31 One or more ranks have chipspare
disabled
—
33 One or more memory ranks are
mismatched and deallocated
Fix memory loading order
(page 2-25)
34 Memory deallocated because of a loading
error
Fix memory loading order
(page 2-25)
35 Memory is not loaded recommended
loading order
Fix memory loading order
(page 2-25)
36 The PDT is full Clear with
pdt
clear
command in
EFI shell
37 At least one (1) CPU has bad fixed core
ratio
—
38 All CPUs were slated for compatibility
deconfig
—
39 Incompatible CPUs detected Call support center
40 CPUs installed with mixed cache sizes This will always cause a stopboot
41 CPUs installed with mixed steppings —
42 All CPUs are over clocked —
43 At least one (1) CPU is over clocked —
44 Monarch changed to lowest stepping CPU Only seen once after monarch is
set to lowest stepping
46 CPUs loaded in wrong order —
48 SAL NVM cleared Information only, no action
required
Error Number Error/Warning Message Solution