D–6 HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Event, Error and Warning Messages
Accessing the Logs with MP Commands
7KH6(/DQG)3/GDWDFDQDOVREHDFFHVVHGIURPWKH03ORJVXVLQJWKH03FDUG
SL
FRPPDQG
/RJVFDQEHGLVSOD\HGLQWKUHHPRGHVUDZKH[WH[WRUNH\ZRUG
03ILUPZDUH(¥7KH
SDM
VHWGLVSOD\PRGHFRPPDQGGHWHUPLQHVWKHIRUPDWRI
WKHGLVSOD\
03ILUPZDUH(RUKLJKHU¥2XWSXWPRGHLVVHOHFWHGIURPDPHQXZKHQWKHORJLV
GLVSOD\HG
+H[0RGH([DPSOH
13 0x203E5F914A0200E0 FFFF010944080300
14 0x5680006300E000F0 010000003E5F914A
14 0x5680006300E000F0 0000000000000000
15 0x203E5F914B020110 FFFF027000120300
7H[W0RGH([DPSOH
Log Entry 13: 28 Feb 2003 16:41:46
Alert Level 2: Informational
Keyword: Type-02 080901 526593
Power supply turned on
Logged by: BMC; Sensor: Power Supply - Pwr Spply 1 Ctrl
Data1: Device Enabled
0x203E5F914A0200E0 FFFF010944080300
Log Entry 14: 28 Feb 2003 16:41:46
Alert Level 2: Informational
Keyword: BOOT_START
CPU starting boot
Logged by: System Firmware 0
Data: Implementation dependent data field
0x5680006300E000F0 0000000000000000
Log Entry 15: 28 Feb 2003 16:41:47
Alert Level 2: Informational
Keyword: Type-02 127002 1208322
Soft Reset
Logged by: BMC; Sensor: System Event
0x203E5F914B020110 FFFF027000120300