Error messages 135
Description: The system encountered an NMI prior to this boot. The NMI source was: Uncorrectable
cache memory error.
Action: Replace the processor.
Insight Diagnostics processor error codes
MSG_CPU_RR_1
Event type: Unable to divide and multiply with zero and infinity.
Action:
Ensure proper ventilation and cooling for the server.
Ensure the processor heatsinks are attached correctly (do not remove them).
Check diagnostics and the Integrated Management Log for heat-related events.
Upgrade to the latest versions of system BIOS and Insight Diagnostics.
Replace the processor.
MSG_CPU_RR_2
Event type: A Pentium floating point bug exists.
Action: Replace the processor.
MSG_CPU_RR_3
Event type: Coprocessor geometric series is out of range.
Action:
Ensure proper ventilation and cooling for the server.
Ensure the processor heatsinks are attached correctly (do not remove them).
Check diagnostics and the Integrated Management Log for heat-related events.
Upgrade to the latest versions of system BIOS and Insight Diagnostics.
Replace the processor.
MSG_CPU_RR_5
Event type: Refresh count is out of range.
Action: Replace the board that contains the memory controller.
MSG_CPU_RR_6
Event type: Unable to perform arithmetic operations on registers.
Action:
Ensure proper ventilation and cooling for the server.
Ensure the processor heatsinks are attached correctly (do not remove them).
Check diagnostics and the Integrated Management Log for heat-related events.
Upgrade to the latest versions of system BIOS and Insight Diagnostics.
Replace the processor.