entity already disabled
Meaning: An already disabled circuit, identified in the object field of the event
message, has received NCLs Disable command.
entity already enabled
Meaning: An already enabled circuit, identified in the object field of the event
message, has received NCLs Enable command.
entity disabled
Meaning: The circuit named in the object field of the event message has been
disabled in response to NCLs Disable command.
entity enabled
Meaning: The circuit named in the object field of the event message successfully
initialized, or has been enabled with the NCLs Enable command.
Error in Configuration record
Meaning: The established configuration for the frame relay circuit is in error.
Action: Modify the configuration to establish a valid frame relay circuit.
Excessive collisions
Meaning: The LAN circuit named in the object field of the event message has
dropped a frame after it has detected collisions on 16 successive
transmission attempts.
Action: If message occurs frequently, investigate the causes of LAN congestion.
Excessive errors; interface disabled
Meaning: For the indicated frame relay circuit, when the DTE receives a
designated number of errors within a designated number of events, the
Event Log Messages