Cleaning the Dust
Filter
The HP Multi-Site Traffic Director Server Appliance SA9200 has a
dust filter element mounted behind the front grille and in front of the
dual intake fans. This filter is washable and should be cleaned every
six months at a minimum. If you use your SA9200 in an abnormally
dusty environment, clean the filter more often. You need not interrupt
SA9200 operation to perform the following cleaning procedure.
To clean the filter:
Remove the two Phillips screws that secure the metal grille on
the left side of the front panel. Remove the grille to expose the
foam filter element.
Remove the filter element from its recess. It is recommended that
you replace the grille and its screws while the filter element is
being cleaned.
Wash the filter in warm water and set aside to dry.
Allow the filter to dry thoroughly before reinstalling in the SA9200.
When the filter element is dry, remove the front grille and replace
the filter in its recess, assuring that its entire perimeter is behind
the metal lip of the recess.
Reinstall the grille with its two Phillips screws.