Vista de página 101
Switch Command Interface (SWCI)
ServerNet Nomadic Disk (Release 2) User’s Guide523968-001
6-32
Command Execution Error Messages
Command Execution Error Messages
These error messages indicate errors during the execution of correctly specified SWCI
commands:
Cause. A SWITCH command failed because the switch card in slot slot-number is
currently locked
Effect. The command is not executed. SWCI waits for the next command.
Recovery. Unlock the switch card, then retry the SWITCH command.
Cause. A LOCK, UNLOCK, or SWITCH command failed because slot slot-number
does not contain a switch card.
Effect. The command is not executed. SWCI waits for the next command.
Recovery. Retry the command and specify a slot that contains a switch card.
Cause. A disk file file-name in a LOG TO command is not an EDIT (code 101) file.
Effect. The command is not executed. SWCI waits for the next command.
Recovery. Retry the command with an EDIT file.
Cause. An error occurred during an attempt to write to the LOG TO file-name log
file.err-num is the Guardian file-system error number that occurred.
Effect. The command is not executed. SWCI waits for the next command.
Recovery. Refer to the Guardian Procedure Errors and Messages Manual for
recovery from the file-system error. Then retry the command.
***ERROR*** Command failed because SC slot-number is
currently LOCKED.
***ERROR*** Command failed because SC slot-number is EMPTY.
***ERROR*** Disk log file file-name is not an edit file.
***ERROR*** Guardian error err-num on access to log file
file-name.
Vista de página 101