2-13
Installing the HP 10/100 Hubs
Sample Network Topologies
Installing the HP 10/100 Hubs
Sample Network Topologies
This section shows you a few sample network topologies in which the HP 10/
100 Hubs are implemented. For more topology information, see the document
Designing HP AdvanceStack Workgroup Networks, which can be found on
the HP network products World Wide Web site, http://www.hp.com/go/
procurve.
For information on 100Base-T network topology rules, see the card “Connec-
tivity Rules for 100T Networks” that is included with your hub.
Connecting End Nodes to HP 10/100 Hubs
“straight-through”
twisted-pair
cables
HP 10/100 Hub
PCs and
peripherals
Server with
“Fast” Ethernet
NIC
Category 5 cable for
100 Mbps connection
to the server
Description Connect end nodes (PCs, workstations, servers, printers and other peripherals) to the HP 10/100
hubs by using “straight-through” twisted-pair cables, as shown in the above illustration. The server
should be connected at 100 Mbps to reduce bottlenecks as multiple users attempt to access the
server.
Cables Used 10 Mbps connections: Category 3, 4, or 5 100-ohm “straight-through” unshielded twisted pair cable
100 Mbps connections: Category 5 “straight-through” unshielded twisted pair cable only
Maximum
Connection
Lengths
100 meters for both 10 Mbps and 100 Mbps connections to end nodes
9934.book Page 13 Thursday, January 14, 1999 12:39 PM