3. Install the spring-loaded clamp’s dowels (A and B below) into the reflector.
Figure 9-9 Installing the dowels into the reflector
4. Repeat this procedure for the other lamp.
Re-install the lamp housings
Re-install the user-end lamp housing
1. Secure the lamp housing to the lamp assembly using the original two lower silver screws on the
user end of the carriage (see screws A in
Figure 9-3 User end screws on page 61 for locations).
●
If you have difficultly fitting the lamp housing back onto the lamp base, loosen the four
screws indicated below.
●
If the lamp housing is still difficult to install, squeeze the side of the lamp base to bend the
side in about 0.8 mm (0.031 in).
Figure 9-10 Loosening screws to ease installation