3. Install the spring-loaded clamp’s dowels (A and B below) into the reflector.
Figure 9-9 Installing the dowels into the reflector
4. Repeat this procedure for the other lamp.
Re-install the lamp housings
Re-install the user-end lamp housing
1. Secure the lamp housing to the lamp assembly using the original two lower silver screws on the
user end of the carriage (see screws A in
Figure 9-3 User end screws on page 61 for locations).
If you have difficultly fitting the lamp housing back onto the lamp base, loosen the four
screws indicated below.
If the lamp housing is still difficult to install, squeeze the side of the lamp base to bend the
side in about 0.8 mm (0.031 in).
Figure 9-10 Loosening screws to ease installation