Figure 54 Computer management
NOTE:
After a rescan or reboot, the multipath information for the LUN can be found in the iSCSI UI. In
addition, t
he system event log records iSCSI Initiator and path information.
2. For Microsoft MPIO, the load balance policies apply to each LUN individually. To d isplay and
modify the LUN load balance policy (see Figure 55):
a. Start the MS iSCSI control panel applet.
b. Select the Target tab.
c. Click Details.
d. Click Devices.
e. HighlightaLUNdevicenameandclickAdvanced.
f. Select the MPIO check box.
g. Select the desired options on the Load Balance Policy menu to set the policy.
EVA iSCSI connectivity user guide
105