Keywords
[MMDDhhmmCCYY]
Specifies the date. This requires an admin session.
Exception: if you omit [MMDDhhmmCCYY],thecurrentdateisdisplayed,which
does not require an admin session.
Notes
Network Time Protocol (NTP) must be disabled to set the time with the Date
command. See “Set command” on page 152 for information about NTP.
Example
The following is an example of the Date command:
mpx100 (adm in) #> date 010314282006
TueJan314:28:002006
mpx100 (admin) #> date
Tue Jan 3 14:28:14 2006
Clear command
Allows you to remove all entries from the mpx100/100b’s log file and/or reset the Fibre Channel and
iSCSI statist
ic counters.
Authority Admin session only to set
Syntax
clear
nl
logs
nl
stats
Keyword
logs
Example
The following is an example of the clear command:
mpx100 #>clear logs
mpx100 #>clear stats
FRU command
Saves and restores the mpx100/100b configuration.
14 4