Starting the mp
x100/100b
To start the mpx
100/100b:
1. Attach the AC power cord to the mpx100/100b and the power distribution unit (PDU). Verify
that the mpx100’s/100b's System Power LED is illuminated.
The mpx100/100
b runs a self-test and begins normal operation.
2. Verify that th
e Heartbeat LED is blinking (once per second) and that the Input Fault LED is not
illuminated.
Figure 10 shows the location of the ports and LEDs on the mpx100 /100 b.
25087a
8
5
6
7
2 3 4
1
Fi gure 10 Th e m px10 0 p ort an d L ED loc a tio ns
1. M an ag e m
ent port (10/100 Ethernet) 2. Heartbeat LED
3. Input P ower LED
4. System Fault LED
5. FC ports 6. iSCSI ports
7. RS – 232 p o r t
8. AC power
Setting the mpx100/100b management port to use HP
StorageWorks Command View EVA
Communication between the mpx100/100b and HP Command View EVA is established through the
IP management port of the mpx100/100b and the IP connection of the HP Command View EVA
application server. This link is necessary for iSCSI device discovery and subsequent iSCSI settings of the
mpx100/100b through HP Command View EVA.
To set the mpx100/100b management port:
1. Use Telnet to connect to the mpx100/100b management port, or connect to the mpx100/100b
serial port using the HP-supplied connector.
NOTE:
The mpx100/100b management port’s default IP address is 10.0.0.1/255.0.0.0.The
mpx100/100b serial p ort's default setting is 115200/8/n/1.
2. Loginwiththeusernameguest and the password password.
3. Enter the comma nd admin start with the password config to enable administrator
privileges.
4. Enter the set mgmt command and follow the prompts to set the management port properties to
enable HP Command View EVA to communicate with the mpx100/100b management port.
EVA iSCSI connectivity user guide
45