Chapter 11 Troubleshooting
173
Event Description
Offset Definition
06 00 PHP slot fault de-asserted
06 05 PHP slot powered on
07 00 PHP slot fault asserted
07 05 PHP slot powered off
BIOS Error Codes\Messages
The following list defines the BIOS error codes on the HP Server rx4610 server
system. All BIOS error codes\messages, when encountered, appears on the video
and are logged in the SEL unless it is full.
The system event log record for these BIOS error codes has a sensor type of ‘0F’.
To decode a BIOS error codes\message, use the last two bytes in the event
description to identify the specific error.
0100: Timer Error
0103: CMOS Battery Low
0104: CMOS Settings Wrong
0105: CMOS/GPNV Checksum Bad
0106: CMOS Display Type Wrong
0108: Unlock Keyboard
0109: Keyboard Error
010A: KB/Interface Error
010B: Memory Size Decrease
010E: Cache Memory Error
0117: Pri Master Drive - ATAPI Incompatible
0118: Pri Slave Drive - ATAPI Incompatible
0119: Sec Master Drive - ATAPI Incompatible
011A: Sec Slave Drive - ATAPI Incompatible
011B: CMOS Date/Time Not Set
011E: Cache Memory Error