Hp Integrity rx4610 Server Manual do Utilizador Página 27

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 26
19
3 Installing Fans and Power
Supplies
Introduction
The fans and power supplies used by the HP Server are hot swappable. The HP
Server has four 172 mm fans located on each side of the chassis and two 120 mm
cooling fans located on the top front of the chassis. The server has a maximum of
four 800 watt autoranging power supplies located in the front of the chassis. This
chapter describes the procedures necessary to remove and to replace these
components.
Tools and Supplies Needed
Phillips (cross-head) screwdriver (#2 bit)
Antistatic wrist strap (recommended)
Pen or pencil
Equipment Log
To record the model and serial numbers of the server, all installed options, and
any other pertinent information about the server, see Appendix B, “Equipment
Log and Configuration Worksheet”.
WARNING Make sure that the rack is anchored securely, so it will not tip
when the server chassis is extended.
Vista de página 26
1 2 ... 22 23 24 25 26 27 28 29 30 31 32 ... 248 249