PAD Services
X.3 Parameter Descriptions
Chapter 6 167
NOTE The values listed for parameter 3 may be combined by specifying the sum
of the values. For example, specifying 10 is the same as specifying 2 and
8.
16 ETX and EOT only.
32 HT, LT, VT, FF only.
64 NUL, SOH, STX, BS, LF, CR, SO, SI,
DLE, DC1, DC3, DC4, NAK, SYN,
ETB, EM, SUB, FS, GS, RS, and US
(all other characters in the first two
columns of the International
Alphabet #5).
126 All characters, except
alphanumerics.
127 All characters are data forwarding.
Table 6-4
X.3 Parameter Description
4 - Idle Timer Specifies a timer duration interval in units of
1/20 of a second. If the time between characters
entered at the terminal exceeds the specified
timer value, the packet being assembled by the
PAD is automatically transmitted. The range is 0
through 255. If 0 is specified, there is no idle
timer and packets will never be transmitted due
to a time-out.
5 - Anc Device
Control
The ancillary device control parameter permits
flow control toward the terminal by the PAD. The
PAD indicates its readiness to receive characters
from the terminal by transmitting X-ON (DC1) or
X-OFF (DC3) to the terminal. 0 indicates that
flow control by the PAD is not operational, and 1
permits flow control by the PAD.