PAD Services
X.3 Parameter Descriptions
Chapter 6 169
8 - Discard
Output
This parameter restores data delivery to the
terminal after the reception of the break
character and value 16 has been specified for X.3
Parameter 7. This value may be modified by the
reception of the break character. 0 indicates
normal data delivery, and 1 indicates that data is
discarded.
9 - Number of CR
Padding Chars
Specifies the number of buffer characters to be
added following a carriage return. This is used for
hard copy terminals to allow time for the carriage
to return to the left side of the page. The range is
0 through 7.
10 - Chars per
Line/Wrap
-Around
Specifies the number of printing characters to be
transmitted before the PAD inserts a carriage
return in the data stream. This parameter is not
needed on terminals with auto-wrap-around. The
range is 0 through 255.
11 - Baud This parameter specifies the terminal access
speed (Baud rate). x29server does not allow
users to change the Baud rate. It defaults to the
terminal Baud rate, which is usually 9600. The
possible values and their associated Baud rates
are listed below.
Table 6-7
Value Ba ud Rate
0 110
1 134.5
2 300
3 1200
4 600
575
Table 6-6 (Continued)
Comentários a estes Manuais