Troubleshooting
Recovering From a Power Failure
Chapter 8208
Recovering From a Power Failure
For Systems With a Backup Power Supply
If your site is equipped with a backup power supply, system memory will
be preserved in the event of power failure. However, because your X.25
hardware does not have backup capability, any on-board RAM-based
memory is lost.
Recovery from a power failure is automatic when the /etc/powerfail
script is invoked by /etc/inittab. Otherwise SMH (or x25init) must
be used to manually re-initialize the interface after a power failure.
The recovery mechanism informs the X.25 driver of the power failure.
The X.25 driver then “marks” the interface as “downand a
DISCONNECT INDICATE is received on all open SVCs.
For Systems With No Backup Power Supply
If your system does not possess the battery backup option, both system
memory and interface card memory are lost. You must reboot your
system.