Service Calibrations
4-2 HP Designjet T Series — Service Manual
Service Calibrations
The Printer has several calibration procedures that must be performed under
certain conditions.
REMEMBER THAT CERTAIN CALIBRATIONS ARE REQUIRED
EVEN IF AN ASSEMBLY HAS BEEN DISASSEMBLED TO GAIN
ACCESS TO ANOTHER ASSEMBLY OR COMPONENT.
The following is a list of all internal service calibrations available in the
Printers. For instructions to enter the service calibrations menu, see
Entering
the Service Calibrations Menu on page 4-4.
1 Scan Axis Calibration. See
Scan Axis Calibration on page 4-4.
The purpose of this Service Calibration is to carry out a PWM check, and
calibrate the int
ensity of the Line Sensor.
2 S
ervice Station Calibration. See
Service Station Calibration on page 4-5.
The purpose of this Service Calibration is to calibrate the Drop Detector
(located
in the Service Station) in relation to the Carriage Assembly.
3 P
aper Advance Calibration. See
Paper Advance Calibration on page 4-6.
The purpose of this Service Calibration is to calibrate the nominal advance
of the
media. This calibration is necessary to control the exact movement of
the media in order to avoid print quality problems like banding.
4 Dr
op Detector Calibration. See
Drop Detector Calibration on page 4-12.
The purpose of this Service Calibration is to calibrate the Drop Detector
(located
in the Service Station) in relation to the Carriage Assembly.
5 L
ine Sensor Calibration. See
Line Sensor Calibration on page 4-15.
The purpose of this Service Calibration is to c
alibrate the intensity of the Line
Sensor. An incorrect calibration can result in edge-detection failures during
media loading and incorrect reading of prints that are used for alignment or
calibration.
6 Ca
rriage PCA. See
Carriage PCA on page 4-18.
The purpose of this Service Calibration is to r
eset the ink short thresholds
after replacing the Carriage PCA.
If ALL the Calibrations need to be performed (for example,
when both the Formatter and the Print Mech PCA have been
replaced), you must perform them in the following order:
Drop Detector/Service Station Calibration.
Line Sensor/Scan Axis Calibration.
Paper Advance Calibration.